  SV-ADSB-470 Installation, Configuration, and Testing 
SkyView System Installation Guide - Revision R    14-9 
  Confirm that the DEVICE line reads SV-ADSB-470. 
  Use the STATUS line to determine whether the SV-ADSB-470 is successfully communicating 
with SkyView. It can also be used to determine whether the as well as if it is able to see any 
ADS-B ground stations. The status line can display any of the following states: 
o  NOT FOUND: The device is not communicating with SkyView. This usually implies a 
connectivity/wiring problem between the SV-ADSB-470 and SkyView, or that the SV-
ADSB-470 is not receiving power. 
o  NO SIGNAL: The device is communicating with SkyView, but data is not being 
received from an ADS-B ground station. This may occur when you are on the ground 
and do not have line-of-sight reception of an ADS-B ground station, or if you are in 
the air and are out of range of all ADS-B ground stations. If there is an ADS-B ground 
station in range, and NO SIGNAL is persistently displayed, it may imply a connectivity 
problem with your ADS-B antenna or an installation issue that is preventing the ADS-
B antenna from receiving ADS-B ground station broadcasts. Note that when in flight, 
the Map Page displays a status widget in its lower left corner that contains the same 
information as this menu status item. That widget will be more useful for 
ascertaining proper operation once you are in the air and are most likely to be 
receiving data from ADS-B ground stations. 
o  RECEIVING: The device is communicating with SkyView AND data is being received 
from an ADS-B ground station. 
  You may also observe the red LED light on the physical SV-ADSB-470 module to confirm 
proper hardware operation: 
o  Flashing Fast: The module is operating normally, is configured and communicating 
with SkyView over a correctly-configured serial port, and is receiving GPS data from 
SkyView. 
o  Flashing Slowly: The module is operating, but is not fully communicating with 
SkyView. 
o  Off: The module is not receiving power. 
o  On Solid - the module is receiving power, but is not operating normally. Contact 
Dynon Technical Support (contact information at the beginning of this manual) for 
assistance if power cycling your avionics does not help. 