Installation guide
 Accessory Installation and Configuration     
15-2    SkyView System Installation Guide - Revision R 
Failure Warning 
Designed to meet the indication requirements of FAR 23.1326, the heated pitot controller has 
an output that can trigger a warning light in the cockpit whenever the probe heater is turned 
off or is not functioning properly. While not required for Experimental and LSA category 
aircraft, this feature provides peace of mind, giving you instant feedback that your probe’s 
heater is working as designed. 
Tools and Materials Required 
  Dynon Avionics AOA/Pitot Probe 
  Two plumbing lines (usually ¼” soft aluminum or plastic tubing) routed from the SV-
ADAHRS-200/201 to the probe mounting location 
  Tubing interface hardware 
o  Reference our wiki at http://wiki.dynonavionics.com for tubing interface hardware 
recommendations. 
  #36 drill and #6-32 tap 
  AOA Pitot Mounting bracket. Models known to work well can be found at 
http://wiki.dynonavionics.com/AOA_Pitot_Brackets_and_Parts. 
Please follow these instructions explicitly as improper installation can result in 
permanent damage to your device and/or aircraft. 
Heater Controller Module Installation 
This section addresses heater controller module installation. If you are installing the unheated 
version of the probe, you may skip to the AOA/Pitot Probe Mounting Section. 