Installation guide
 Accessory Installation and Configuration     
15-14    SkyView System Installation Guide - Revision R 
Figure 97–Encoder Converter Module Electrical Connections 
Serial Port Setup–DYNON CONVERTER Format 
Enter the Serial Port Setup Menu (SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP)  on 
each display and configure the appropriate serial port for use with the Encoder Serial-to-Gray 
Code Converter module with the following settings: 
SERIAL # IN DEVICE:  NONE 
SERIAL # IN FUNCTION:  NONE 
SERIAL # IN/OUT BAUD RATE:  1200 
SERIAL # OUT DEVICE:  DYNON CONVERTER 
TX
GND
Green Wire
Black Wire
SkyView Display Serial Transmit
Shared Ground
Encoder Converter
Module
SkyView Display
DB37 Connector
A1
A2
A4
B1
B2
B4
C1
C2
C4
D4
Strobe
Yellow
Green
White/Blue
Blue
Orange
White/Red
White/Green
White
White/Black
Unconnected
Unconnected
Transponder
Red
Black
10-30 volts
Ground
The Encoder Converter Module
is compatible with all SkyView
display serial ports. 