Installation guide
    System Planning 
SkyView System Installation Guide - Revision R    2-7 
SV-ADAHRS-200 and SV-ADAHRS-201 
Proper installation of the SV-ADAHRS-200/201 module(s) is critical. PFD 
performance is significantly linked to a proper ADAHRS installation. The 
installation location must meet all of the mechanical, magnetic, orientation, and 
environmental requirements detailed below. 
An SV-ADAHRS-200/201 installation location should be a rigid surface within 12 feet 
longitudinally and 6 feet laterally of the aircraft's center-of-gravity. Figure 1 illustrates this 
criterion. 
Figure 1–SV-ADAHRS-200/201 with Respect to Center-of-Gravity 
The location should also be magnetically benign. Given that it may be difficult or impossible to 
avoid all sources of magnetic interference, it is possible to characterize and compensate for 
small, static magnetic fields with calibration. Calibration cannot, however, compensate for 