Installation guide
   SV-COM-X83 Installation, Configuration, and Testing 
SkyView System Installation Guide - Revision R    17-17 
Power/Ground Input 
The SV-COM-T8 and SV-COM-PANEL require 10-30V DC. 20 AWG wire is recommended for 
power and ground wires for the SV-COM-T8. For all other connections, 22 AWG wire is 
recommended. 
SV-COM-T8 
Pin 
SV-COM-PANEL 
Pin 
Notes 
13 
6 
ENABLE 
SV-COM-T8 -> SV-COM-PANEL 
5 
5 
DATA OUT 
SV-COM-PANEL -> SV-COM-T8) 
6 
4 
DATA IN 
SV-COM-T8 -> SV-COM-PANEL 
Table 60 - SV-COM-PANEL to SV-COM-T8 Interconnections 
Optional Flip / Flop Button 
Pin 7 of the SV-COM-PANEL can be connected to a Push Button Normally Open (PBNO) and 
GROUND. Pushing this button “flip flops” the ACTIVE and STANDBY frequency selection - the 
same function as pressing in the TUNE knob on the SV-COM-PANEL. Typically this signal is used 
with a button on the stick. 