Installation guide
System Planning     
2-12    SkyView System Installation Guide - Revision R 
Mounting Requirements 
Some SkyView modules include mounting fasteners, while some do not. Mounting fasteners are 
included as a convenience and installers are not required to use them. Use sensible mounting 
techniques when installing equipment in suitable locations. You should reference individual 
equipment chapters for information regarding installation instructions. 
SkyView System Construction 
Appendix C: Wiring and Electrical Connections contains complete details regarding 
pin-outs of all SkyView system component connectors and wire harness colors. 
Overview 
A SkyView system consists of displays, modules, and connection hardware. Displays manage 
power for modules (not servos) and control communication between devices. Modules provide 
data to the displays. The connection between displays and modules is referred to as a SkyView 
network. 
SkyView Network 
Displays and modules utilize standardized 9-pin D-sub (from now on referred to as “D9”) 
network connectors and are compatible with premade connection hardware—network cables, 
splitters, and connector gender changers. Servos have un-terminated wires and we recommend 
the use of one servo cabling kit (SV-NET-SERVO) per servo. All of this connection hardware is 
available from Dynon. 
Harnesses and Cables 
Dynon’s display harness and network cables use aircraft-grade Tefzel® wiring. The display 
harness breaks out power, serial, USB and other important pins from the back of the display. 
Network cables are available in a variety of lengths. The 3 and 6 foot cables have female D9 
connectors on both ends. The longer cables have a female D9 connector on one end and open 
pins on the other end. The open end allows installers to run the cable in and through areas that 
would not be possible if a connector was present. The connector is installed after the cable has 
been run. 
The servo cabling kit (SV-NET-SERVO: one kit per servo) makes it easy to connect the SkyView 
system to servos and includes 20 feet of pre-twisted wire (twisted pair 22 AWG wire for data; 
20 AWG wires for power), D9 connectors, connector shells, crimp contacts, an insertion tool, 
heat shrink, and zip ties. It is recommended that you read and understand Appendix C: Wiring 
and Electrical Connections before working with this kit. 