Installation guide
SkyView System Installation Guide - Revision R    24-1 
24. Appendix E: Serial Data Output 
Any of SkyView’s five RS232 serial ports can be configured to output various types of serial data 
via SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP. Technical information on the 
installation and connection to the serial ports can be found in the Serial Devices section of the 
SkyView Installation Guide. To output serial data, you must select either DYNON EMS, DYNON 
ADAHRS, DYNON SYSTEM, DYNON ADAHRS + SYSTEM, DYNON ADAHRS + EMS, or DYNON 
ADAHRS + SYS + EMS, NMEA OUT (BASIC), or NMEA OUT (FULL) as a Serial Out device, select a 
baud rate, and connect the serial port to an external serial device such as a PC. The serial data 
can be logged using any standard serial terminal program, a data logger program, or dedicated 
data logger device. All numbers are output in decimal except where noted and are standard 
ASCII. To view the data using a terminal program, that program should be configured to receive 
data in the following format: 
  Baud rate: Set baud rate to match the baud rate selected on SkyView’s serial port 
  Data:    8 bit 
  Parity:    none 
  Stop:    1 bit 
  Flow control:  none 
Multiple SkyView display systems: SkyView’s serial ports are designed in a way 
that allows serial transmission to continue, uninterrupted, as long as at least one 
SkyView display is operational. SkyView accomplishes this by transmitting from 
only one display’s serial ports in a multi-display system. SkyView manages which 
display is the “actual transmitter” automatically to avoid serial port conflicts. 
However, the display that transmits is not user-selectable. Therefore, for reliable 
serial reception in multi-display systems, a SkyView serial data output wire must 
be wired from each display, in parallel, to the external serial device that is being 
used to capture SkyView’s serial data. 