Installation guide
    Appendix E: Serial Data Output 
SkyView System Installation Guide - Revision R    24-7 
DYNON EMS Serial Data Format 
The following section details the format of EMS data output to the serial port: 
Position 
Width 
Name 
Pin 
Description 
1 
1 
Start 
Character 
'!' 
2 
1 
Data Type 
3 = EMS Data. Other Dynon formats look 
similar, and may be interleaved, this bit 
indicates what kind of data will follow. 
3 
1 
Data Version 
Currently 2. This is the version of the data 
represented below and will change if there 
is a future version that changes data. Data 
version changed at SkyView version 5.1. 
4 
8 
System Time 
HHMMSSFF, current Zulu time according to 
SkyView's internal clock which is 
synchronized with GPS time if GPS is 
available. HH is the hour from 00 to 23. 
MM is the minute from 00 to 59. SS is the 
second from 00 to 59. HHMMSS are '--------' 
if GPS time has never been available. FF is 
the 1/16-second fraction counter from 00 
to 15, and may skip digits if baud rate is too 
low to send data at 16Hz. 
12 
3 
Oil Pressure 
(PSI) 
Varies 
(see note 1) 
000 to 999 or XXX. Oil pressure in 
PSI. There must be a pressure sensor 
named "OIL" for this to work. See note 2. 
15 
4 
Oil Temp 
(deg C) 
Varies 
(see note 1) 
+/- then 000 to 999 or XXX. Oil 
temperature in C. There must be a 
temperature sensor named "OIL" for this to 
work. See note 2. 
19 
4 
RPM L 
C37 P32/34 
0 to 9999. RPM from Left input. 
23 
4 
RPM R 
C37 P33/35 
0 to 9999. RPM from Right input. 
27 
3 
Manifold 
Pressure 
(inHg) 
C37 P26 
0 to 600. Manifold Pressure in 0.1 inHg. 
299 = 29.9 inHg. There must be a pressure 
sensor named "MAP" for this to work. See 
note 2. 
30 
3 
Fuel Flow 1 
(gal/hr) 
C37 P14 
000 to 999. Fuel flow in 1/10th Gallons Per 
Hour. 086 = 8.6 GPH. See note 2. 
33 
3 
Fuel Flow 2 
(gal/hr) 
C37 P19 
000 to 999. Fuel flow in 1/10th Gallons Per 
Hour. 086 = 8.6 GPH. This is usually return 
flow. See note 2. 