Appendix E: Serial Data Output     
24-8    SkyView System Installation Guide - Revision R 
Position 
Width 
Name 
Pin 
Description 
36 
3 
Fuel 
Pressure 
(PSI) 
Varies 
000 to 999 or XXX. Fuel pressure in 1/10th 
PSI. 274 = 27.4 PSI. 
There must be a pressure sensor named 
"FUEL" for this to work. See note 2. 
39 
3 
Fuel Level L 
(gal) 
Varies 
000 to 999 or XXX. Fuel level in 1/10th 
Gallons. 128 = 12.8 Gallons. 
There must be a Level sensor named 
"LEFT" for this to work. If there is no "LEFT" 
OR "RIGHT" but there is a "MAIN", this will 
be MAIN. See note 2. 
42 
3 
Fuel Level R 
(gal) 
Varies 
000 to 999 or XXX. Fuel level in 1/10th 
Gallons. 128 = 12.8 Gallons. 
There must be a Level sensor named 
"RIGHT" for this to work. See note 2. 
45 
3 
Fuel 
Remaining 
(gal) 
Fuel 
Computer 
000 to 999 or XXX. Fuel level in 1/10th 
Gallons. This is derived from the fuel 
computer and is based on the fuel on 
board added set by the user and the 
decremented by fuel flow. See note 2. 
48 
3 
Volts 1 
C37 P1 
000 to 360 in 1/10th Volts. 284 = 28.4 volts. 
See note 2. 
51 
3 
Volts 2 
C37 P2 
000 to 360 in 1/10th Volts. 284 = 28.4 volts. 
See note 2. 
54 
4 
Amps 
C37 P24/25 
+/- then 000 to 999. 1/10th Amps. -083 = -
8.3A. See note 2. 
58 
5 
Hobbs Time 
Calculated 
00000 to 99999. In 1/10 hours. 12345 = 
1234.5 hours. 
63 
5 
Tach Time 
Calculated 
00000 to 99999. In 1/10 hours. 12345 = 
1234.5 hours. 
68 
4 
Thermocoup
le 1 (deg C) 
C25 P2/14 
+/- then 000 to 999. In degrees C. See note 
2. 
72 
4 
Thermocoup
le 2 (deg C) 
C25 P3/15 
+/- then 000 to 999. In degrees C. See note 
2. 
76 
4 
Thermocoup
le 3 (deg C) 
C25 P4/16 
+/- then 000 to 999. In degrees C. See note 
2. 
80 
4 
Thermocoup
le 4 (deg C) 
C25 P5/17 
+/- then 000 to 999. In degrees C. See note 
2. 
84 
4 
Thermocoup
le 5 (deg C) 
C25 P6/18 
+/- then 000 to 999. In degrees C. See note 
2. 
88 
4 
Thermocoup
le 6 (deg C) 
C25 P7/19 
+/- then 000 to 999. In degrees C. See note 
2. 