Installation guide
Appendix E: Serial Data Output     
24-10    SkyView System Installation Guide - Revision R 
Position 
Width 
Name 
Pin 
Description 
196 
6 
GP Input 13 
C37 P31 
+/- then 0000 to 9999, then units. +YYYYZ. 
See note 3. 
202 
16 
Contacts 
Not used in 
SkyView 
Z*16 (ZZZZZZZZZZZZZZZZ). 
218 
3 
Percent 
Power 
000 to 199 in percentage of engine 
reference power. XXX when not 
determined or invalid. 
221 
1 
EGT Leaning 
State 
The state of EGT leaning. L: Lean of peak, P: 
Peak, R: Rich of peak. X when not 
determined or invalid. 
222 
2 
Checksum 
The 1 byte sum of all 217 preceding bytes. 
In ascii-hexformat, so 3A = 0x3A. 
224 
2 
CR/LF 
Carriage Return, Linefeed = 0x0D, 0x0A. 
Table 85 – Dynon EMS Serial Output Format 
Note 1: These sensors can be connected to various pins on the EMS 37-pin D-sub connector 
(D37). See the SkyView Installation Guide for more information. 
Note 2: If the value is invalid, or out of range for the sensor, or the sensor is not configured, or 
if the sensor is configured but not calibrated, then an 'X' is output for each character in the field 
instead of a value.  
Note 3: Units for each GP input depends on the type of sensor that is connected to the pin. 
See GP Inputs 
Rotax 912 iS Note: When the engine type is 912iS, the following fields in the serial output 
source their data from the 912 iS’s computer instead of conventional sensors: Oil Pressure, Oil 
Temp, RPM L, RPM R, Manifold Pressure, Fuel Flow 1, Fuel Flow 2 (always 0). 
GP Inputs 
The output for GP input pins is: 
  Each output is in the format +YYYYZ 
o  + is the +/- sign for the value 
o  YYYY is the value of the signal 
o  Z is the units for the signal 
  C if the signal is in temperature, and the units are 1/10th degrees C 
  YYYY is 1/10th degrees C, so 1234 = 123.4 C 
  XXXX if the signal is out of range (red X on ems page) 
  ZZZZ if the input is not configured 
  P if the signal is in pressure, and the units are 1/10 PSI 
  YYYY is 1/10th PSI, so 0123 = 12.3 PSI 
  XXXX if the signal is out of range (red X on ems page) 