Installation guide
  SV-D700 / SV-D1000 / SV-D1000T Installation and Configuration 
SkyView System Installation Guide - Revision R    4-7 
Electrical Installation 
Use this section in conjunction with the information contained in Appendix C: Wiring and 
Electrical Connections (notably Figure 125 on page 22-8). The wires and wire colors in this 
section refer to the wires on the included SkyView Display Harness (SV-HARNESS-D37). 
Some wires that are used in SkyView harnesses are identified with secondary color 
stripes. Exposing these striped wires to solvents or abrasives can cause the stripe 
color to wear off. Handle these wires with care. 
Power Input 
SkyView displays have a primary power input that is compatible with 12 volt and 24 volt 
systems (10 to 30 volts DC). There are two unterminated solid red primary power input wires 
(to reduce current loading in each wire—these are not for redundancy and both must be 
connected to the same power source) and two unterminated solid black primary ground wires. 
Ensure that there is an appropriately rated circuit breaker or replaceable fuse on 
the primary power input. Reference the  
Power Consumption Section of the System Planning Chapter for more information. 
Grounding 
Ensure that all external devices that interface with SkyView have a common ground with 
SkyView. If a device does not share ground with SkyView, it may not communicate properly. 
Airplane Master Contactor / Relay Considerations 
If your aircraft is equipped with a master contactor or a relay that is operated by the master 
switch, it is imperative that the coil of the contactor or relay is protected by a diode to reduce 
the voltage spike seen when the contactor is turned off. Without this diode, the aircraft system 
can see spikes above 100V, which can damage Dynon equipment and other avionics. 
While some contactors have this diode internally, many do not. Please verify the existence of 
this diode before operating your Dynon equipment. Any diode that is rated for more than 1A 
and more than 50V is suitable. Vans Aircraft part number ES DIODE MASTER is also a suitable 
option. 
Backup Battery Connection and Operation Rules 
SkyView displays have the option of an external backup battery (SV-BAT-320). The display 
harness has a connector that mates with the connector on the backup battery. Simply 
connecting the display to the battery using this connector enables backup battery functionality. 
In the event of an electrical failure that causes SkyView to run on the SV-BAT-320, the SV-BAT-
320 supplies power to the SkyView display it is connected to, along with any connected SV-
ADAHRS-200/201, SV-EMS-220/221, SV-ARINC-429, and SV-GPS-250 modules. A fully charged 