Specifications

2
Supplies 20 Valcom power units for
powering Valcom one-way amplified
speakers (1 Amp -24VDC); Additional power
supplies are required for a quantity of
speakers using over 20 power units
Page with music outputs (2 provided); music
mutes during page
Page without music output
Battery backup input (Use Valcom VPB-260
battery backup supply)
Time clock/single tone (Contact closure
activated)
Night ring/warble tone (Closure or 90VAC
activated)
Priority sequence of tones:
Page overrides music
Night ring mixes with music and page
Time clock mixes with music and page
Individual switches for selection of night ring
and time clock tones per output
May be used with 25 or 70 Volt amplifiers
AC powered, 115 or 230VAC
Internationally recognized power connector
AC input fused at 1 Amp @ 115VAC, 60Hz
or 0.5 Amp @ 230VAC, 50Hz
115/230 Volt selector switch for international
use
UL listed
Dimensions/Weight
7.06"H x 9.00"W x 2.40"D
(17.93cm H x 22.86cm W x 6.10cm D)
Weight: 3.7 lbs. (1.68 kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dBm nominal
Output Impedance: 8 Ohms
Output Level: -10dBm nominal
DC Output: 1 Amp at -24VDC
Nominal Power Requirements
Voltage: Current:
115VAC 1.0 Amp
230VAC 0.5 Amp
Battery Backup
The V-2001A is equipped with a standard
3-prong polarized MOLEX connector to allow
connection of a fused output (3 Amp) battery
backup supply (Valcom VPB-260 or equivalent)
in case of AC power failure. Backup time will be
a function of system usage.
Use a cord set consisting of a minimum 18
AWG cord and grounding type attachment
plug rated a minimum of 15A, 250V. The
cord set should have the appropriate safety
approvals for the country in which the
equipment will be installed and should be
marked HAR.
The socket outlet shall be installed near the
equipment and shall be easily accessible.
NOTE: The AC line cord of the VPB-260 and
the AC line cord of the V-2001A should be
plugged into the same AC circuit.
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in
this manual is the customer premise
equipment such as an electronic key system,
a PABX or a dedicated single line
telephone(s). The V-2001A is not intended
for direct or indirect connection to the public
telephone network or to PABX analog station
ports. When used with a customer premise
telephone system such as a key system
or PABX system, these units are interfaced
to the system via a fully protected page port
or system central office port, which is a fully
protected interface device. Also, the host
system must be configured to disallow
central office trunk conferencing in order to
prevent indirect connection to the public
network.
Precautionary Designations
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN