Specifications

2
Night ring/warble tone
(Closure or 90VAC activated)
Priority sequence of tones:
Page overrides music
Night ring mixes with music and page
Time clock mixes with music and page
Individual switches for selection of night ring
and time clock tones per output
May be used with 25 or 70 Volt amplifiers
AC powered, 230 or 115VAC
Internationally recognized power connector
AC input fused at 0.5 Amp @ 230VAC, 50 Hz or 1
Amp @ 115VAC, 60 Hz
115/230 Volt selector switch for international use
UL listed
Dimensions/Weight
7.10" H x 9.00" W x 2.40" D
(18.03cm H x 22.86cm W x 6.10cm D)
3.7 lbs. (1.68kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm nominal
Voice Switch Sensitivity: -21dBm
Music Source Input Impedance: 8 to 600 Ohms
Music Input Level: -10dBm nominal
Output Impedance: 8 Ohms
Output Level: -10dBm nominal
DC Output: 1 Amp at -24VDC
Nominal Power Requirements
Voltage: Current:
230VAC 0.5 Amp
115VAC 1 Amp
The V-2001A-E is equipped with a standard 3-prong
polarized MOLEX connector to allow connection of a
battery backup supply in case of AC power failure.
Use a cord set consis ting of a minimum 18 AWG
cord and grounding type attachment plug rated a
minimum of 15A, 250V. The cord set should have
the appropriate safety approvals for the country
in which the equipment will be installed and
should be marked HAR.
The socket outlet shall be installed near the
equipment and shall be easily accessible.
Environment
Temperature: 0 to 40 Degrees C
Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in this
manual is the customer premise equipment such
as an electronic key system, a PABX or a
dedicated single line telephone set(s). The
V-2001A-E is not intended for direct or indirect
connection to the public telephone network or to
PABX analog station ports. When used with a
customer premise telephone system such as a
key system or PABX system, these units are
interfaced to the system via a fully protected page
port or system central office port, which is a fully
protected interface device. Also, the host system
must be configured to disallow central office
trunk conferencing in order to prevent indirect
connection to the public network.
Precautionary Designations
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Mounting
The V-2001A-E was designed for wall or table
mounting. Secure unit to wall studs or a suitable
brace away from heat sources or strong magnetic
fields (Motors, fans, power supplies, etc.) with the
control and terminal strip accessible. Four wood
screws are included for mounting.