Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Flush Mount Installation 1. Mount the flush mount box into the wall. 2. Connect the ground wire into the flush mount box using the tooth lockwasher and the machine screw nut (included in the kit). 3. Disconnect the red filter from the display panel. 4. Connect the wiring as shown on the wiring diagram. 5.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Flush Mount Installation Flush Mount Picture 2.5” Figure 1 Front View: Side View Flush Mount Angled View: D3 = .28” D4 = 3.5” H = 4.65” H = 4.65” W = 10.3” Flush Mount Picture 4.0” Figure 2 Front View: Front view: Side View Flush Mount Angled View: D3 = .28” D4 = 3.5” H = 7.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Surface (Wall) Mount Installation 1. 2. 3. 4. 5. 6. Mount the wall mount box into the double gang box using four machine screws (#6-32) included in the kit. Connect the ground wire into the flush mount box using the tooth lockwasher and machine screw nut (included in the kit). Disconnect the red filter from the display panel. Connect the wiring as shown on the wiring diagram.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Metal Double Mount Installation 1. 2. 3. 4. Screw hanger/mounting rod (included in the kit) into the crossbar (also included in the kit). Insert wires through hanger/mounting rod. Install crossbar using two (2) #6-32 screws into double gang box. Mount the double mount box into the clock base using two (2) #6 nuts and Tooth Lockwasher #6. (The double mount can be mounted either on the wall or on the ceiling).
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Plastic Surface (Wall) Mount Installation q Mount Housing to Wall and/or Gang Box - To mount the housing to the wall, drive two (2) plastic anchors into the wall (not supplied in kit) and take two pan head screws (also not supplied in kit) and drive them into the plastic inserts leaving an 1/8th inch gap between the head of the screw and the wall.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Plastic Double Mount Installation *For metal mounting bracket: Use a wall anchor that can support 50 lbs or more with a maximum screw size of 10/1.5” q Install metal mounting bracket - First, remove the metal mounting bracket from the inside of the double mount base by unscrewing the two (2) 6-32 x 1/2” screws located on the underside of the base (save these screws for step #5).
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Plastic Double Mount Installation t Snap and screw base to metal mounting bracket - Snap the base to the metal mounting bracket by first making contact with the lip in the upper side of the base and the metal mounting bracket.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Interfacing with Other Systems 59 Minute Correction Description: 110 VAC/24 VAC 60 Hz is used to run the clock normally. Applying an eight (8) second reset signal from 57 minutes and 54 seconds will cause an hourly correction. Applying a fourteen (14) second reset signal from 5:57:54 will cause a daily correction. Instructions: 1. In programming mode, set option 31 to 05. 2.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Interfacing with Other Systems National Time/Rauland Description: 110 VAC/24 VAC 60 Hz is used to run the clock normally. Applying a 25 second reset signal when minutes equal 00 and seconds equal 00 will cause an hourly correction. Applying a 24 minute reset signal when hours equal 06 or 18 and minutes equal 00 and second equals 25 will cause a daily correction. Instructions: 1.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Interfacing with Other Systems Rauland Digital Description: Applying a half second pulse for every minute to the Dig. Line will bring the clock to the correct time. The clock will jump to the correct time at the end of the correction pulse. Note: For better synchronization, it is recommended to work on a 60 Hz time base. Note: Use only an isolated transformer to run the clock in 24 volt mode. Instructions: 1.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Programming Setting the Time on the Digital Clock 1. To set the time, press the top button to change the hour and/or the bottom button the set the minute. Set Hour Set Minute Programming the Digital Clock Use the following options to program a once-a-day pulse output. Enter the programming mode by pushing the “Set Hour” and “Set Minute” buttons at the same time.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Option 4 - Set 12/24 Hour Mode: Use the bottom button to scroll between “12 or 24”. Option 5 - Daylight Savings Time: Press the bottom button to scroll between “d”, “1”, or “2”. “d” will disable this option. “1” will enable daylight savings pre 2007. “2” will enable daylight savings post 2007. Option 6 - Alternating Time/Date Display: Press the bottom button to scroll between “E” or “d”.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Option 9 - Set the Clock Number: Use the bottom button to scroll between “001-999”. This two-step function allows the user to program the address (clock number and zone number) for the display for numeric messaging. Option 10 - Set the Zone Number: Press the bottom button to scroll between “00-99”. This allows for the second step, programming of the two-digit zone number for numeric messaging.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Option 14 - Set the Loss of Communication Alert: Use the bottom button to scroll between “01-10”. This option allows the user to set when the colons will flash after the clock loses data to indicate loss of communication. Press the “Set Minute” button to scroll between “01-10”.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Option 24 - Once a Day Pulse Output - Set Duration: Use the bottom button to scroll between “01-99”. This option allows the user to set the duration of the relay closure (in seconds) Option 30 - Auxiliary Input Control: Use the bottom button to scroll between “E” and “d”. If the option is set to “d” (disable), the following option will be 40. Setting the option to “E” (enable) will enter an input control mode.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Option 34 - Once a Day Pulse Input - Set Duration: Use the bottom button to scroll between “01-59”. This option allows the user to set the second(s) they want the clock to go to. Option 40 - Activating Diagnostic Mode: Use the bottom button to scroll between “E” and “d”. If the option is set to “d” (disable), pressing the top button will take the user back to the time.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Relay Output Selections “d” = Disables the relay output selection mode. “1” = 58th minute (1) - The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. & 5 p.m.) is ten correction cycles sent to the relay (each for 95 seconds) beginning at 5:05:00, 5:07:00, 5:09:00, 5:11:00, 5:13:00, 5:15:00, 5:17:00, 5:19:00, 5:21:00, and 5:23:00.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Support Frequently Asked Questions Can the V-D11025A or V-D11040A digital clock be used as an independent clock? Yes, the clock is capable of being used as an independent, slave, master or chronograph clock. Some clocks require a 9 volt battery backup for timekeeping. What happens to the V-D11025A or V-D11040A if a power failure occurs? The V-D11025A or V-D11040A come equipped with a 10 year battery backup.
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 540-563-2000 P. 540-362-9800 F. www.valcom.com Support Troubleshooting The clock is not running. What do I do? a) Measure the input voltage to the clock. The voltage should measure 85-135 volts in the 110 volt model or 10-28 volts in the 2.5”/24 volt model and 16-28 volt in the 4.0”/24 volt model. b) Make sure the transformer is an isolated transformer if using a 24 volt model. c) Make sure the ground wire is not touching other wires.