Specifications

Heater model installaon and operaon manual
Clearances to combustible material
1 MINIMUM CLEARANCE MUST BE 14” 350 MM ON THE SIDES OF A FLUE WITH A 3.5”
90 MM THICK OUTER SHELL.
2 MINIMUM CLEARANCE MUST BE 20” 500 MM ON THE SIDES OF A FLUE WITH ONLY
A 2.375” 60 MM THICK OUTER SHELL.
3 MINIMUM CLEARANCE ABOVE THE HEATER MUST BE 10” 250 MM.
4 THE HEATER MUST BE ASSEMBLED ON A 2” 50 MM THICK NONCOMBUSTIBLE SUR
FACE OR FOAMGLASS TYPE INSULATING MATERIAL.
5 WHEN A NONHEATING SHELF OR BENCH 3” 75 MM THICK OR LESS IS ATTACHED
TO THE HEATER, IT CAN BE OVERLOOKED FOR PURPOSES OF CLEARANCES.
6 CLEARANCES FOR KITCHENETTES ARE 20” 500 MM IN ALL DIRECTIONS.
7 7 WHEN THE HEATER IS IN A CUBICLE, SIDE CLEARANCES INCREASE FROM 14” 350
MMTO 20” 500 MM.
e clearances shown in this section have been determined by test according to procedures set out in safety
standards ULC S627 (Canada), UL1482 (U.S.A.) . When the stove is installed so that its surfaces are at or
beyond the minimum clearances specied, combustible surfaces will not overheat under normal and even
abnormal operating conditions.
No part of the stove or ue pipe may be located closer to combustibles than the minimum clearance gures
given.
Location of the Certication Label
Since the information given on the certication label axed to the appliance always overrides the informa-
tion published, in any other media (owners manual, catalogues, yers, magazines and/or web sites) it is im-
portant to refer to it in order to have a safe and compliant installation. In addition, you will nd information
about your stove (model, serial number, etc.). You can nd the certication label on the back of the stove.
Clearances to Walls and Ceiling
e clearances to combustible walls may be slightly dierent in Canada and the U.S.A. and may also dier
depending on whether you use single or double wall ue pipe. Please be sure to choose the correct clearance
for your location and type of ue pipe. See gure Clearances to combustible materials and oor protection
to match each letter to a clearance.
18