Between underside
of header and bottom
of firebox
No hearth required.
If using a hearth,
see page 23.
1/2” thick non-combustible
cement board required above,
on each side and below
engine opening (NOT supplied)
- see page 36.
NOTE: Height of cavity may be affected
by vent configuration with clearance
- see page 26.
NOTE: This unit requires a
solid platform to support it.
Combustible framing allowed
beneath fireplace. When the
appliance is installed directly
on carpeting, tile or other
combustible material other
than wood flooring, the
appliance shall be installed
on a metal or wood panel
extending the full width
and recessed depth of the
appliance
43”
51-1/4”
*18-1/2”
Critical!
This dimension is total
framing cavity depth not
including any wall finish.
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
CONSULTEZ LE GUIDE D’INSTALLATION
Min. 53” (1346 mm)
40” (1016 mm)
Min. 44-1/2” (1130 mm)
Min.
20-1/2”
(521 mm)
14-3/4”
(375 mm)
Min.
9-1/4”
(235 mm)
Min. 6-1/2”
(165 mm)
Min. 6-1/2”
(165 mm)
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMENT
Flush with bottom of unit;
add extra cement board
if overlapping framing.
Minimum coverage area of non-combustible cement board.
Any wall nish applied to shaded area must be non-combustible.
Linear 1600 replace outline
(including stand-os)
Non-combustible
cement board
required
thickness:
1/2 inch (13 mm)
Joints preferred at corners
to prevent cracking
NON-COMBUSTIBLE MATERIALS ONLY
READ INSTRUCTIONS
MATÉRIAUX INCOMBUSTIBLES SEULEMEN
T
CONSULTEZ LE GUIDE D’INSTALLATION
Framing Requirements
Framing Dimensions
Minimum Cement Board Dimensions (required for both sides of fi replace)
QUALIFIED
INSTALLER