Owner`s manual

7
WARNING
CHOKING HAZARD! Ensure that the replace
area is clear of re glass or vermiculite particles as
these could be ingested by small children. Vacuum
thoroughly around the replace area after cleaning.
Pilot Flame
Thermocouple Probe
must be in Flame
WARNING
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the replace front after
maintenance.
!
Long Beach Driftwood Kit Correct Flame Picture
Murano Glass Fire Correct Flame Picture
Decorative Glass Correct Flame Picture
Pilot Flame can
be seen left of
the re bed
Pilot Flame can be seen
between the front and
rear left logs
ing agents nor polishes should be used. Dry stains can
be removed using a white or light colored cloth with mild
soap and warm water when the material is cool, then
dried immediately. If the stain is hard to remove, use a
white or light colored synthetic scrub pad (not steel wool)
and dry immediately. In case of an accidental spill, soak
up the liquid IMMEDIATELY with a dry cloth and follow
up with a wipe down with a wet cloth.
Clean the barrier screen dusting it with a soft brush.
Clean the rebox ceramic logs/rocks and walls dust-
ing them with a soft brush. Glass liners can be cleaned
with household glass cleaner. Dust can also be re-
moved from the burner using a soft brush after remov-
ing the ceramic logs. When cleaning, make sure that
no particles are brushed into the slots of the burner.
To re t the window:
1. Place it in its bottom railing and push its top against
the rebox.
Ensure to remove any vermiculite
or glass particles in the railing before
installing the window.
2. While you hold it, pull the side levers back into the
window brackets on each side.
3. Apply light hand pressure against the window frame
sides to bed-in the window seal.
4. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Owners Information
IMPORTANT: To ensure a safe operation, verify
that the levers are hooked properly to the window
tabs; then, pull out the top of the window and
release it to insure the springs return it.
Also, double-check that the bottom of the window
frame is correctly installed in its the bottom railing.
!
5. Reinstall the barrier screen on the trim.
a) 1555 1” trim: Insert the screen’s top tabs in the
slots in the convection baf e then rest the screen
bottom tabs on the edge of the opening in the
plinth to lock it in position.
b) 1550 3.5” and 1570 trims: Hook the bottom
of the screen to the bottom edge of the trim’s
front plate, then, with the top levers up, push the
screen against the replace. Rotate the levers
down to hook them up to the trim and slide them
inwards to secure them.
6. Verify that the screen is properly hooked to the trim
and secure.
Checking Pilot and Burner Flames
A periodic check of the pilot and burner ames should
be made. Check after the re has been on for at least
30 minutes. The pilot ame must cover the tip of the
thermocouple probe. The main burner ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Hot Glass Warning Plate
OWNER’S