Owner`s manual

Front view,
left side
Top view, left side
Flex connector redirected using one elbow.
Flex connector redirected using two elbows.
Common ttings required (not supplied)
3/8” elbow
+ short 3/8”
nipple
OR
3/8” street
elbow(s)
(where al-
lowed)
1. Remove ex connector.
2. Remove ared connector.
3. Install new inlet elbow.
4. Add ared connector to new
elbow and t ex connector.
Close the access panel.
Alternate Inlet Connection
In cases where local codes do not permit the ex
connector to be used inside the appliance case,
reconnect the ex connector outside of the appliance
case. A cut-out is provided in the appliance case for
this purpose.
Cut-out
Option 1
Option 2
4. Add another elbow, the ared
connector and re t the ex
connector. Direct it towards
the rear of the appliance or
downward.
Close the access panel.
Supply Gas Installation
Use common elbow and ttings (not
supplied) to redirect the position of
the ex connector. NOTE: the ex
connector bend radius must be no
smaller than the size of a golf ball
(approx. 1-3/4” or 44 mm).
26
QUALIFIED
INSTALLER