Owner`s manual

16
Co-Axial Venting
HORIZONTAL
TERMINATION
2-PIECE
WALL
THIMBLE
PIPE
LENGTH
PIPE
LENGTH
PIPE
LENGTH
PIPE
LENGTH
90˚ ELBOW
CEILING
FIRESTOP
ATTIC
FIRESTOP
ATTIC
INSULATION
SHIELD
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
Important Installer Notice – Weather Sealing &
Vapor Barriers
It is the installer’s responsibility to ensure that vent
installations through exterior walls are caulked and
weatherproofed in such a manner as to:
Prevent rain water from entering the wall from the weather
side by adequately caulking the outer vent plate to the
exterior wall surface.
Prevent moisture inside the home from penetrating into the
wall structure by ensuring the inside wall plate is adequately
sealed to the inside vapor barrier.
Prevent rain water and moisture from entering the walls by
sealing the joints between the outer vent tube and the inner
and outer wall plates.
We recommend the use of a high quality polyurethane sealant.
Typical Co-axial Venting Components
INSTALLATION