Owner`s manual

Connect Venting
IMPORTANT: This appliance’s venting system is room sealed and there-
fore, does not require room air to be used in the combustion process.
1. Rough-in two 3” diameter vent liners into the existing chimney
system from the roof. Be careful not to tear or damage the liners in
the process. It may be easier to install both liners at the same time
rather than one at a time. Leave plenty of liners at the bottom to
facilitate the connection of the liners to the vent slider. It is best to
leave the top termination until later.
Designate and mark the top and bottom of one liner as
“EXHAUST” to avoid confusion later.
2. a) Large cavity opening
Slide the appliance into the cavity.
b) Smaller cavity opening
Release the two screws retaining the vent slider to the front
of the rebox.
Remove the slider from the rebox by sliding it towards the
back of the rebox.
3. Apply RTV sealant to the collars on the vent slider and t the
two liners ensuring that the exhaust liner is connected to
the identi ed “EXHAUST” vent collar. Secure with 4 tapping
screws per liner.
If the vent slider was removed from the rebox, slide the rebox
onto the vent slider in the cavity taking care not to damage the
liners. Make sure that the rear edge of the slider is hooked
over the cleat on the rebox. Secure the vent slider to the
front of the rebox with two screws removed earlier.
4. From the roof, pull
the liners and t the
ashing.
5. Fit the terminal
cap ensuring that
the exhaust liner
is connected to
the exhaust vent
collar. Secure with
screws.
6. Seal the terminal
and ashing from
water penetration
as required.
1
3
4
5
Installation
option 2b
option 2a
6
Vent slider
cleat
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts
speci cally approved with this
appliance may result in property
damage or personal injury.
!
24
QUALIFIED
INSTALLER