Dimensions & Clearances
Corner clearances Wall clearances
Mantel / shelf clearances
Min. 2”
between
combustible
wall and
stove
Min. 2” between
combustible wall
and stove
Min. 2” between
combustible wall
and side of stove
Min. 2”
between
combustible
wall and rear
of stove
17-7/8”
28-1/2”
32-1/2” minimum
42” minimum
26” maximum
Alcove clearances
2” between
combustible
wall and
back of stove
Keep a minimum
of 36” of space
in front of stove
free of furniture
or object
Min. 36”
A
B
30-1/2”
17-7/8” 2”
Clearances
The instructions in this manual cover installation
of the Madrona Traditional Stove (MF28 engine
+ MFCS01 or MFCS02 Traditional Castings).
For installation of the Madrona Contemporary
Stove (MF28 engine + MFCS04), use this
manual jointly with the instruction manual
provided with the MFCS04 kit.
Mantel / shelf clearances
Mantel
Depth ‘A’
0–1”
(0–26 mm)
2–5”
(51–127 mm)
6–18”
(152–457 mm)
19–24”
(483–610 mm)
Mantel
Height ‘B’
34”
(864 mm)
36”
(914 mm)
38”
(965 mm)
42”
(1067 mm)
INSTALLATION