Owner`s manual
15
Venting
KEY VENT TERMINAL LOCATIONS - MINIMUM DISTANCES MINIMUM
CLEARANCE
Inches Cm
A Clearance above grade, verandah, porch, deck or balcony 12 30
B Clearance to window or door that may be opened 12 30
C Clearance to permanently closed window (recommended to prevent condensation on window) 12 30
D Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet
(60 cm) from the center-line of the terminal
18 46
E Clearance to unventilated soffi t 12 30
F Clearance to outside corner 12 30
G Clearance to inside corner 12 30
H Horizontal clearance to center-line of meter/regulator assembly located within 15 feet (4.6 m) below
the terminal
36 90
I Clearance to service regulator vent outlet 36 90
J Clearance to non-mechanical air supply inlet to the building or the combustion air inlet to any other
appliance
12 30
K Clearance to a mechanical air supply inlet 72 180
L Clearance above paved sidewalk or a paved driveway located on public property
Note: A vent must not terminate directly above a sidewalk or paved driveway, which is located
between two single-family dwellings and serves both dwellings
84 210
M Clearance under a verandah, porch, deck or balcony
Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the
fl oor
12 30
Note:
Local codes and regulations may require different clearances.
Horizontal Vent Termination
• The vent terminal must be located on an outside wall or
through the roof.
• This direct vent appliance is designed to operate when
an undisturbed airfl ow hits the outside vent terminal
from any direction.
• The minimum clearances from this terminal that must be
maintained when located on an outside wall are shown
in the fi gure below.
V
G
A
Min. 72”
Max. 72”
Alcove detail
(open on one
side) Normal
ceiling/soffi t
clearances
apply.
Any reduction in these clearances could result in a
disruption of the airfl ow or a safety hazard. Local codes
or regulations may require greater clearances.
• The vent terminal must not be recessed into a wall or
siding.
• The vent terminal should be positioned where it will not
be covered by snowdrifts.
• 551DVK sidewall vent termination requires the terminal
guard 835TG when accessible—within 7 ft of ground.