Owner`s manual

25
Front & Top Installation
Front Installation
Hook the cast front to the side brackets located
between the engine and the cast sides.
Cast front
Hook
Details
Engine
Side bracket
Air Shutter
Operation Check
Turn the replace ame up and down using the
remote control to con rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 30–34.
Aeration Settings
Light the re and allow the unit to warm up for 10–15
minutes to evaluate the ame picture. The burner
is equipped with an adjustable shutter to control
primary aeration. See the gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Operation Check & Aeration Settings Adjustment
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
Open
Open
Close
Close
NG
NG Air Shutter
Slider & Cover
In a few unusual installations, the ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic logs and window installed.
Increasing aeration will cause the ames to appear
more transparent and blue making the ceramic logs
glow more.
Decreasing aeration will cause the ames to appear
more yellow or orange making the ceramic logs glow less.
Too little aeration may result in black carbon
forming and dropping into the rebox.
The instructions in this manual cover installation
of the Madrona Traditional Stove (MF28 engine
+ MFCS01 or MFCS02 Traditional Castings).
For installation of the Madrona Contemporary
Stove (MF28 engine + MFCS04), use this
manual jointly with the instruction manual
provided with the MFCS04 kit.
INSTALLATION