Owner`s manual
5
Options
Fuel
RF24DVN—Natural Gas Installations
RF24DVP—Propane Gas Installations
Decorative Cast Iron Frets
RA24CV—Contemporary, Vintage Iron Finish
RA24AV—Avant-Garde. Vintage Iron Finish
RA24TB—Traditional, Black Finish
Venting
Pipe—generic 3” diameter fl exible aluminum liner 
approved for gas venting.
Specifi cations
Approvals and Codes
This appliance is certifi ed to ANSI Z21.88-2007/CSA 
2.33-2007  Vented Gas Fireplace Heater standard for 
use in Canada and the USA and to CGA 2.17-N91 High 
Altitude Standard in Canada. This appliance is for direct 
vent installation terminating at the roof only.
Model RF24DVN is for use with Natural Gas only.
Model RF24DVP is for use with LPG only.
Conversion between fuels may only be done using the 
approved conversion kits listed above.
This appliance complies with CGA P.4.1, Testing 
method for measuring annual fi replace effi ciencies.
Ratings
Termination—Miles Industries’ 559CLT Co-Linear 
Termination. 559SFK Square Flashing Kit required for 
terminating existing masonry chimney applications.
Circulating Fan
555CFK—Circulating Fan Kit with 6’–0” c/w grounded 
cord set.
Conversion Kits
RA24NK—to convert from LPG to Natural Gas
RA24PK—to convert from Natural Gas to LPG
*High Altitude Installations
Input ratings are shown in BTU per hour and are 
certifi ed without deration for elevations up to 4,500 feet 
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, 
installations must be in accordance with the current 
Model RF24DVN RF24DVP
Gas Natural Propane
Altitude (Ft.) 0-4,500 Feet*
Input Max. (Btu/h) 24,000 24,000
Input Min. (Btu/h) 10,500 10,500
Manifold pressure (in w.c.) 3.95 9.5
Min. Supply pressure (in w.c.) 5.0 11.0
Max. Supply pressure (in w.c.) 10.5 14.0
Main Burner Injector
Catalogue Number (this is not a drill size)
Bray Cat.
#82-580
Bray Cat.
#92-260
Pilot Injector
Catalogue Number (this is not a drill size)
S.I.T.
#62
S.I.T.
#30
The installation must conform to local codes or, in the 
absence of local codes with the National Fuel Gas Code, 
ANSI Z223.1 or the Canadian Installation Code CAN/
CGA-B149. Only qualifi ed licensed or trained personnel 
should install this appliance.
This appliance, when installed , must be electrically 
grounded in accordance with local codes, or in the 
absence of local codes, with the National Electrical 
Code, ANSI/NFPA 70 or the Canadian Electrical Code, 
CSA C22.1
ANSI Z223.1 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370 m).
This appliance is intended for installation into existing masonry or factory-built, solid-fuel burning fi replaces 
only. 