Owner`s manual

7
Vent Con gurations
10’
15’
20’
25’
30’
35’
40’
4’6”
5’0”
5’6”
6’0”
6’6”
7’0”
7’6”
8’0”
9’0”
10’0”
8’6”
9’6”
3” Liners
3” min. Bend
Radius
Vertical Vent Height
Allowable Horizontal Offset
10’ min. - 40‘ max.
559CLT
Co-Linear Terminal
See
Chart
559CLT
Termination
3” Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
10”
10”
Allowable Vent Con gurations
The RF24 is certi ed for use with approved 3” diameter exible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system. The venting system must terminate vertically at the roof
using an approved termination cap. Both inlet and exhaust liners must be run continuously from appliance to roof
termination. Where possible, avoid joints in ex pipe. If joints are required, use only connectors approved by the
manufacturer of the ex pipe. Field fabricated joints are not allowed.
Any generic 3” diameter exible venting approved for venting gas appliances is acceptable.