Installation guide

4. CONTROLS (CONT’D)
For more convenience, this unit can also be controlled using an optional main wall control.
NOTES: 1. The integrated control must be turned OFF to use an optional main control.
2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.
4.2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS
Use the terminal connector included in the installation kit to perform the electrical
connection for main and optional wall controls. Check if all wires are correctly inserted in
their corresponding holes in the terminal block. (A wire is correctly inserted when its
orange receptacle is lower than another one without wire. On picture at right, wire A is
correctly inserted, but not wire B.)
CAUTION
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit between themselves
or by touching any other components on the wall control. Avoid poor wiring connections. To reduce electrical interference
(noise) potential, do not run wall control wiring next to control contactors or near light dimming circuits, electrical motors,
dwelling/building power or lighting wiring, or power distribution panel.
WARNING
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric shock or
damage of the wall control or electronic module inside the unit.
0
!
A
B
VE0106
4.2.1 ELECTRICAL CONNECTION TO LITE-TOUCH BRONZE MAIN WALL CONTROL
NO C NC I OC OL Y R G B
B G
OC
MAIN WALL CONTROL
LITE-TOUCH BRONZE
and
SIMPLE TOUCH BRONZE
REAR VIEW
G
B
Y
VE0101A
4.2.2 ELECTRICAL CONNECTION TO BRONZE MAIN WALL CONTROL
NO C NC I OC OL Y R G B
VE0103
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
D
I T
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
MIN.
MAX.
OFF
M
O
R
E
H
U
M
I
D
L
E
S
S
H
U
M
I
D
C
O
M
F
O
R
T
Z
O
N
E
-30 °C
-22 °F
-20 °C
-4 °F
-5 °C
23 °F
5 °C
41 °F
- 11 -