Installation manual
60-MINUTE CRANK TIMER:
Activate the timer.
Results expected:
1. Motor speed: high for up to
60 minutes.
2. Air exchange indicator light
goes “ON”.
9.2 AUXILIARY CONTROLS
First, turn OFF the main control device before checking the remote auxiliary controls.
20
9.
Overall Verification (cont’d)
20/40/60-MINUTE PUSH-BUTTON TIMER:
Activate the push button. Within
2 seconds, push one time for
20 minutes, two times for
40 minutes or three times for a
60-minute activation.
Results expected:
1. Motor speed: high for 20,
40 or 60 minutes.
2. Indicator light goes “ON”
and flashes every 5 seconds (one time to
indicate a 20-minute operation, two times
for a 40-minute, and three times for a
60-minute operation).
3. Air exchange indicator light goes “ON”.
NOTE: To stop activation, push one more time.
VC0041
20 min.
40 min.
60 min.
®
OFF
10
20
30
40
50
60
TURN
PAS T
20
VC0017
• Review with the user the steps required for the regular maintenance of her/his ventilation
system. These steps are described in detail in the user manual:
• Warn the user of the necessity to rebalance the system following a major house renovation or following
the installation of any extra registers.
• Make sure the user understands how to use the main control as described in the user manual.
10.
Maintenance/Instructions for User
FOUR TIMES A YEAR:
• Inspect the intake hood, and clean if needed.
• Clean the filters.
• Clean the interior of the cabinet and clean the door.
• Clean the condensation tray and inspect the drain tubing.
ONCE A YEAR:
• Clean the heat recovery core.
• Clean the blades of the blower wheels if needed.
WARNING
Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the
unit from its power source.
!
CAUTION
Do not oil the motor. It is already permanently lubricated.