® USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, AND ENERGY RECOVERY VENTILATOR MODEL ERV 90H-V ECM VB0124 VB0125 VB0127 VB0137 PLEASE READ AND SAVE THESE INSTRUCTIONS These products earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. They meet ENERGY STAR requirements only when used in Canada. 08373 rev.
Congratulations! You have made an excellent choice! The operating principle of your Heat Recovery Ventilator or your Energy Recovery Ventilator will give you personal comfort you have never known before. We have prepared this User Guide especially for you. Please read it carefully to ensure you obtain full benefit from your unit. Over the coming months, you will increasingly appreciate the feeling of living in a more comfortable house.
TABLE OF CONTENTS 1. DEFROSTING MODE . . . . . . . . . . . . . . . . . . . . . . . 4 2. CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 2.1 BOOTING SEQUENCES . . . . . . . 2.2 INTEGRATED CONTROL . . . . . . . 2.3 PLATINUM MAIN CONTROL . . . . . . 2.4 DECO-TOUCH MAIN CONTROL . . . . 2.5 LITE-TOUCH BRONZE MAIN CONTROL. 2.6 BRONZE MAIN CONTROL . . . . . . 2.7 OPTIONAL AUXILIARY CONTROLS . . . . . . . . . . 2.7.1 20-MINUTE LIGHTED PUSH BUTTON . . 2.7.
1. DEFROSTING MODE When the outside temperature is below -5°C (23°F), recovery of heat in HRV units creates frost in the core. For ERV units, when the outside temperature is below -10°C (14°F), recovery of energy creates frost in the core. To maintain its proper operation, the unit is programmed to defrost the recovery core. The defrost frequency varies according to the outside temperature. During the defrost cycle, the unit shifts to maximum speed and the dampers close.
2. CONTROLS (CONT’D) 2.2 INTEGRATED CONTROL All units are equipped with an integrated control, located under the unit, on the recessed side of electrical compartment. Plug the unit. Use the push button (1) to control the unit. The LED (2) will then show on which mode the unit is in. 2 VD0207 1 BOTTOM OF THE UNIT Refer to table below to see how to operate the unit using its integrated control.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) AND For more convenience, these units can also be controlled using a main control. Only one main control can be connected per unit. NOTES: 1. The integrated control must be turned OFF to use a main control. 2. If an optional auxiliary control is used, if activated, this auxiliary control will override the optional main control.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) (CONT’D) AND PLATINUM WALL CONTROL KEYS AND INDICATORS (CONT’D) POWER INDICATOR This indicator, located in the upper left side of the wall control, illuminates when the control powered on.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) (CONT’D) AND HOW TO SET PREFERENCES In order to benefit from all of the features of your wall control, the preferences must be set. Table below shows all available settings.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) (CONT’D) AND SETTING PREFERENCES PROCEDURE NOTE: While setting Preferences, the corresponding setting value flashes (e.g.: while setting current hour, hour is flashing). Press and hold MODE/PREF key for 3 seconds to access the setting menu. MODE PREF NOTE: You can exit Preferences setting by pressing on MODE/PREF for 3 seconds any time in the process, or wait 60 seconds.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) (CONT’D) AND HOW TO SET PERIODS FOR PROGRAM MODE (CONT’D) TO CHANGE THESE VALUES: SET Press SET key for 3 seconds. 3 SEC. PROG (for Program) will appear on screen and week days will flash.
2. CONTROLS (CONT’D) 2.3 PLATINUM MAIN CONTROL (FOR HRV 90H-V ECM, ERV 90H-V ECM 60H NOVO+ UNITS ONLY) (CONT’D) AND HOW TO SET PERIODS FOR PROGRAM MODE (CONT’D) SET Press SET key to confirm the choice and go to select the ventilation speed or type. Ventilation speeds and type will flash. MODE PREF SET SMART OR Use the arrow keys to select the ventilation speed or type. SET Press SET key to confirm the choice and go to setting daily period 2.
2. CONTROLS (CONT’D) 2.4 DECO-TOUCH MAIN CONTROL (ALL UNITS) BACKLIGHT If the backlight is not illuminated, the first button pressed (no matter which button) shall turn on the backlight. The backlight remains illuminated for 10 seconds after the last button pressed. VC0120 OPERATING MODES OR To change the operation modes of the ventilation unit, press the UP or DOWN arrow button. Operating mode label will then scroll up or down on LCD screen.
2. CONTROLS (CONT’D) 2.4 DECO-TOUCH MAIN CONTROL (ALL UNITS) (CONT’D) HOW TO SET THE RELATIVE HUMIDITY (RH) LEVEL AND CHOOSE BETWEEN OFF IN STAND BY OR RECIRCULATION IN STAND BY* Setting the relative humidity level allows to select the maximum desired indoor humidity level (in percentage). This value will be used to start the dehumidistat override (air exchange on high speed). Press and hold OK for 3 sec. to access the setting menu. The backlight will be activated during all the procedure. 3 sec.
2. CONTROLS (CONT’D) 2.4 DECO-TOUCH MAIN CONTROL (ALL UNITS) (CONT’D) DEHUMIDISTAT OVERRIDE SELECTION In the operating modes MIN, MAX, 20 min./h. and RECIRC (if available), the user can select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached.
2. CONTROLS (CONT’D) 2.5 LITE-TOUCH BRONZE MAIN CONTROL (FOR 90H-V UNIT ONLY) MAX MIN INTERMITTENT Activate the push button; the color of the indicator shows the unit operating mode. L-T ® VC0080 Color Mode Suggested Use GREEN Intermittent Select this mode when you are away from the house for a few days. Also, when you deem the inside air is too dry in heating season, or too humid during cooling season.
2. CONTROLS (CONT’D) 2.6 BRONZE MAIN CONTROL (FOR 90H-V UNIT ONLY) Adjusting AIR SUPPLY CONTROL % RE HUMID MO ATIVE HUM ID IT REL Y 20% MFO RT ZONE 5°C+ 41°F+ 25% CO HUMIDITY CONTROL OFF 1) Select “MIN” or “MAX” using slide switch (A).
2. CONTROLS (CONT’D) 2.7 OPTIONAL AUXILIARY CONTROLS (CONT’D) 2.7.2 20/40/60-MINUTE PUSH-BUTTON TIMER (FOR HRV 90H-V ECM, ERV 90H-V ECM AND 60H NOVO+ UNITS ONLY) Location: Located in the bathroom or in other locations where there is temporary humidity excess or pollutants. Purpose: To eliminate excess humidity produced by showers or other periodic activities producing pollutants. Within 2 seconds, push once for 20 minutes, twice for 40 minutes or three times for a 60-minute activation. Results expected: 1.
3. MAINTENANCE ! WARNING Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. When cleaning the unit, it is recommended to wear safety glasses and gloves. Refer to illustration at right to identify the inner parts of your unit. 2 1 VD0210 1) HRV or ERV core 2) Core filters 3.1 SEMI-ANNUAL MAINTENANCE 1. Turn the unit off and unplug the unit. A 2.
3. MAINTENANCE (CONT’D) 3.1 SEMI-ANNUAL MAINTENANCE (CONT’D) CAUTION Make sure to align proper symbol on the core (circle or square) with the one on the unit. 8. Slide the cleaned core into the unit. 9. Slide the cleaned filters into the unit. NOTE: The mesh side of filters must be on bottom (rests on core surface). VD0209 10.Reinstall the door. Secure it with both mechanical screws 8-32 x 1” previously removed, plug back the unit and turn it on.
4. TROUBLESHOOTING (CONT’D) PROBLEMS TRY THIS 3. Nothing works. • See if the unit is plugged in. • See if the unit is receiving power from the house circuit breaker or fuse. 4. Condensation on windows (air too humid). • See Controls Section on pages 4 to 17. • Leave curtains half-open to allow air circulation. • Store all firewood in a closed room with a dehumidifier or in a well ventilated room, or store the wood outside. • Do not adjust the thermostat of your heating system below 18°C (64°F). 5.