Instruction Manual
DIGITMR S2 USER’S MANUAL REV 1
57
e. The following screen will be displayed:
Press the [5] key (O-C-O) to select the OPEN-CLOSE-OPEN timing operation.
f. The following screen will be displayed:
Using the keypad, enter the delay time (in milliseconds) between the OPEN-CLOSE
operation, and then press the [ENTER] key.
g. The following screen will be displayed:
Using the keypad, enter the delay time (in milliseconds) between the CLOSE-OPEN
operation, and then press the
[ENTER] key.
h. The following screen will be displayed:
Press and hold down the [ARM] switch, and then press the [START] key. Continue to
hold down the
[ARM] switch.
HOLD "ARM" UNTIL
TEST COMPLETES
"START" TO BEGIN
"STOP" TO ABORT
C-O DELAY in MS:
(10 - 350)
MSEC
"ENTER" WHEN DONE
O-C DELAY in MS:
(10 - 350)
MSEC
"ENTER" WHEN DONE
TIMING MODE:
1. OPEN 2. CLOSE
3. O-C 4. C-O
5. O-C-O