User guide

DIGITMR USER’S MANUAL REV 3
21
3.5 Performing Timing Tests
3.5.1. Timing an OPEN Operation With No Insertion Resistors
To time an OPEN operation with no insertion resistors:
a. Start from the “START-UP” menu:
Press the [1] key (TIME BRKR) to start a test.
If a previous test shot is in the DigiTMR’s memory, the following screen will be
displayed:
1. SAVE SHOT
If you would like to save the previous shot in memory, press the [1] key (SAVE
SHOT). The following screen will be displayed:
Press the [ENTER] key. The following screen will be displayed:
Once the record is saved, the following screen will be displayed:
Press the
[ENTER] key and you will be returned to the “START-UP” menu. Re-
start at step a.
2. CONTINUE (NO SAVE)
SHOT SAVED
SAVING IN PROGRESS
PLEASE WAIT
SAVE SHOT # 0001
TEST: OPEN
DATE: 04/12/09
“ENTER” TO PROCEED
PREV SHOT NOT SAVED
1. SAVE SHOT
2. CONTINUE (NO SAVE)
1. TIME BRKR 04/17/09
2. GET RSLT 10:49:23
3. SET-UP
4. DIAGNOSTICS