User Manual
Auto‐Ohm200S3/DMOM‐200S3/DMOM‐600USER’SMANUAL REV2
24
Connecttheexternalcurrentprobetothegroundcableandthenturn
ontheprobe.Pressanykeyandcontinuetostepc.
c. Thefollowingscreenwillbedisplayed:
TheAuto‐Ohm200S3providesaconvenientautomatictestmodethatcanbeusedto
performmultipletestswithouthavingtorestarteachtestmanually.Whenperforming
anautomatictest,theAuto‐Ohmwillsensewhencablesaredisconnectedandre‐
connectedandwillinitiatethetest2secondsaftersensingare‐connection.
Pressthe[1]key(NORMALTEST)ifyouwouldliketoperformanormaltest.Continue
tostepd.
Pressthe[2]key(AUTOMATICTEST)ifyouwouldliketoperformanautomatictest.
Continuetostepd.
d. Thefollowingscreenwillbedisplayed:
Auto‐Ohm200S3DMOM‐600
Selectthetestcurrentbypressingthecorrespondingnumerickeyonthekeypad.Ifthe
testcurrentyouwouldliketouseisnotlisted,pressthe[6]key(CUSTOM)andthen
enteravaluefrom1Ato200AfortheAuto‐Ohm200S3/DMOM‐200S3or10Ato600A
fortheDMOM‐600.
NOTE
WhenusingaDMOM‐600withinputpowerof100‐120Vac,themaximum
recommendedtestcurrentis300A.
Ifyouhadselectedthenormaltestmode,continuetostepe.
Ifyouhadselectedtheautomatictestmode,continuetostepf.
NOTE
Foranautomatictest,theburn‐intimeis5secondsandcannotbe
changed.
select test current:
1. 10A 2. 25A
3. 50A 4. 100A
5. 200A 6. 400A
7. 600A
8. CUSTOM
select test current:
1. 10A
2. 25A
3. 50A
4. 100A
5. 200A
6. custom
1. NORMAL TEST
2. AUTOMATIC TEST