User Manual

AutoOhm200S3/DMOM200S3/DMOM600USER’SMANUAL REV2
24
Connecttheexternalcurrentprobetothegroundcableandthenturn
ontheprobe.Pressanykeyandcontinuetostepc.
c. Thefollowingscreenwillbedisplayed:
TheAutoOhm200S3providesaconvenientautomatictestmodethatcanbeusedto
performmultipletestswithouthavingtorestarteachtestmanually.Whenperforming
anautomatictest,theAutoOhmwillsensewhencablesaredisconnectedandre
connectedandwillinitiatethetest2secondsaftersensingareconnection.
Pressthe[1]key(NORMALTEST)ifyouwouldliketoperformanormaltest.Continue
tostepd.
Pressthe[2]key(AUTOMATICTEST)ifyouwouldliketoperformanautomatictest.
Continuetostepd.
d. Thefollowingscreenwillbedisplayed:
AutoOhm200S3DMOM600

Selectthetestcurrentbypressingthecorrespondingnumerickeyonthekeypad.Ifthe
testcurrentyouwouldliketouseisnotlisted,pressthe[6]key(CUSTOM)andthen
enteravaluefrom1Ato200AfortheAutoOhm200S3/DMOM200S3or10Ato600A
fortheDMOM600.
NOTE
WhenusingaDMOM600withinputpowerof100120Vac,themaximum
recommendedtestcurrentis300A.
Ifyouhadselectedthenormaltestmode,continuetostepe.
Ifyouhadselectedtheautomatictestmode,continuetostepf. 
NOTE
Foranautomatictest,theburnintimeis5secondsandcannotbe
changed.
select test current:
1. 10A 2. 25A
3. 50A 4. 100A
5. 200A 6. 400A
7. 600A
8. CUSTOM
select test current:
1. 10A
2. 25A
3. 50A
4. 100A
5. 200A
6. custom
1. NORMAL TEST
2. AUTOMATIC TEST