Inspect Rewind Starter (161400,
235400, 245400)
1. Inspect starter pulley for cracks, rough
edges, wear or burrs in pulley groove (A),
wear on spring cup lugs (B) and center
hole ([C] Fig. 14). Replace pulley if
damaged or worn.
Fig. 14
2. Inspect starter housing eyelet (A), center
pivot post (B) and inner spring retainer
([C] Fig. 15). Replace housing assembly if
worn or damaged.
Fig. 15
Assemble Rewind Starter (161400,
235400, 245400)
1. Place spring and cup in pulley, with outer
end of spring (A) between two wide
spaced lugs (B) in pulley and spring cup
projections ([C] Fig. 16) next to the two
wide spaced lugs.
Fig. 16
Fig. 17
2. Note location of inner spring tab (A) and
location of inner spring anchor ([B] Fig.
17) on center post of starter housing.
3. Lower starter housing on to pulley and
spring assembly, then invert assembly.