h. The following screen will be displayed:
Select the phase to test by pressing the corresponding numeric key. For this example,
we will be testing phase H/X1-H/X0, so press the [1] key.
i. The following screen will be displayed:
Select the test current by pressing the corresponding numeric key on the keypad. Press
the [6] key (CUSTOM) if you would like to enter a custom test current and then enter
the current (between 1A-40A) on the next screen.
j. The following screen will be displayed:
1. YES
Press the [1] key (YES) if you wish to convert readings to standard temperature. The
following screen will be displayed:
CONVERT READINGS TO
STANDARD TEMP?
1. YES
2. NO
SELECT TEST CURRENT:
1. 1A
2. 5A
3. 10A
4. 20A
5. 40A
6. CUSTOM
SELECT PHASE:
1. H/X1-H/X0 (YN PH A)
2. H/X2-H/X0 (YN PH B)
3. H/X3-H/X0 (YN PH C)
4. H/X1-H/X3 (Δ PH A)
5. H/X2-H/X1 (Δ PH B)
6. H/X3-H/X2 (Δ PH C)