1.2.2. WRM-40 Technical Specifications
Table 2. WRM-40 Technical Specifications
TYPE Portable transformer winding resistance meter
PHYSICAL SPECIFICATIONS 25”W x 8.5”H x 20”D (63.5 cm x 21.6 cm x 50 cm); Weight: 44 lbs (20 kg)
INPUT POWER 100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz
(Please see the voltage setting notes in section 2.1)
RESISTANCE READING
RANGE
1 micro-ohm – 500 ohms
ACCURACY 1 – 19,999 micro-ohms: ±0.5% reading, ±1 count;
20 – 999 milliohms: ±1% reading, ±1 count;
1 – 500 ohms: ±1.5% reading, ±1 count
TEST VOLTAGE 36 Vdc max
TEST CURRENT RANGE Auto range, 40 Amperes max
DISPLAY Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight
and low-light levels
PRINTER 2.5-inch wide built-in thermal printer
KEYPAD Rugged membrane keypad (10 alpha-numeric keys, 6 function keys)
INTERNAL TEST RECORD
STORAGE
Stores 63 test records of 48 readings each
COMPUTER INTERFACE One RS-232C (19,200 Baud) port
PC SOFTWARE Windows
®
XP/Vista-based software is included with purchase price
SAFETY Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2 standards
ENVIRONMENT Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-
22˚F to +158˚ F)
CABLES Three 50-foot test cables, ground cable, power cord and cable bag
OPTIONS Transportation case
WARRANTY One year on parts and labor