The 52-20 Isolator has been designed to operate in the most severe environments. The 52-20 has
been designed to meet the requirements for the 12Vdc Medical Equipment stated in section 3.7.6 of
the GSA specification KKK-A-1822F.
Maximum Amperage: 20 Amps
Input Voltage: 0-30 Vdc
Max Ambient temperature: -67ºF to +257ºF (-55ºC to +125ºC)
Fuse or Circuit Breaker 20 Amps max.
Customer supplied overload protection must be in series with +12Vdc
input, and should be 25% greater.