Owners Manual INCORPORATED Dual Low Voltage Disconnect Model – DLVD24-3010 Owner's Manual - D913539 Dual Low Voltage Disconnect DLVD24-3010 1
Owners Manual INCORPORATED - + - + Fuse 12V Battery 12V Battery Control Signals P1 Vin P2 DLVD24-3010 10 Amp Load 33 Amp Load Figure 1 2 Typical Dual Low Voltage Disconnect Installation Dual Low Voltage Disconnect DLVD24-3010
Owners Manual INCORPORATED 1 2 3 4 5 6 Table of Contents Introduction .................................................................................................................................4 1.1 Specifications ....................................................................................................................................5 1.2 Standard Features.............................................................................................................................
Owners Manual INCORPORATED 1 Introduction Thank you for purchasing Vanner’s Dual Low Voltage Disconnect (DLVD). We are confident that you will be satisfied with its performance and its features. With proper installation and care, you can look forward to years of service from this high performance product. This document will describe the operation, technical specifications, installation procedures, and accessories.
Owners Manual INCORPORATED 1.1 Specifications Model DLVD24-3010 Specifications DC Input Voltage DC Input Voltage Range DC Input Current Temperature 24 VDC nominal 12-32 VDC 43 Amps Nominal 52 Amps Max .0035 Amp 32 VDC Max 10 VDC Min 10ms Min 33 Amps Nominal 38 Amps Limited 10 Amps Nominal 13 Amps Limited -40˚C to +80˚C Dimensions Weight 4.75”W x 3.31”H x 3.50”D 1.6 Lbs.
Owners Manual INCORPORATED STANDARD FEATURES 1.2 Standard Features 1. Automatic shutoff for Overload 2. Automatic momentary shutoff/restart for over temperature 3. Four wire pulse control 2 SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 2.1 1 2 3 4 5 6 2.2 1 2 3 4 5 6 7 6 General Precautions Do not expose the DLVD to direct water spray or snow.
Owners Manual INCORPORATED 3 Component Identification Figure 2 DLVD Component Identification 7 1 2 6 5 3 0.25 +24V IN 3.000 4 30A OUT 8 0.19 4.38 0.250 Dimensions are in inches Deutsch DT15-6P Receptacle 1 – Deutsch Connector Pin 1 On a +24V logic level high on pin 1, connectivity between Vin (Batt) and P2 out is inhibited. 2 – Deutsch Connector Pin 2 On a +24V logic level high on pin 2, connectivity between Vin (Batt) and P2 out is enabled.
Owners Manual INCORPORATED 4 – Deutsch Connector Pin 4 On a +24V logic level high on pin 3, connectivity between Vin (Batt) and P1 Out is enabled. 5 – Deutsch Connector Pin 5 (P1) This is the 10 Amp output pin. Dependencies are controlled by deutsch pins 3 and 4, as noted above. 6 – Deutsch Connector Pin 4 Ground Reference for control signals. 7 – Voltage stud Vin (Batt) Terminal for connecting the input voltage to the device. 8 – Voltage stud P2 Out This is the 33 Amp output stud.
Owners Manual INCORPORATED 4 4.1 INSTALLATION Unpacking the DLVD Inspect the shipping container and equipment for loose or damaged parts. If any damage is found, immediately notify the freight carrier. 4.2 DLVD Installation Considerations The wiring of your DLVD installation should conform to the National Electric Code (NEC) and any other state or local codes in effect at the time of installation. These codes have been written for your protection and their requirements should be followed.
Owners Manual INCORPORATED 6 PREVENTIVE MAINTENANCE There are no user serviceable components inside the device. For service refer to the Vanner Incorporated Service Department or other qualified service personnel. 6.1 Maintenance Items For continued reliability and safety, a maintenance program should be implemented to include the following: 1 2 3 6.2 Check air ventilation openings for dust and other obstructions. Examine for any surfaces that are discolored or deformed due to excessive heat.
Owners Manual INCORPORATED Notes: Dual Low Voltage Disconnect DLVD24-3010 11
Owners Manual INCORPORATED Vanner Incorporated 4282 Reynolds Drive Hilliard, Ohio 43026 1-800-AC POWER (1-800-227-6937) Tel: 614-771-2718 Fax: 614-771-4904 www.vanner.com e-mail: pwrsales@vanner.