VANNER Incorporated Owners Manual Max Charger 24Volt 42 Amp Three Stage Battery Charger Models: SP00155, SPC0182, SPC0184 Models: SP00143, SP00180, SP00181, SPC0187 Max Battery Charger Page 1 Owner’s Manual
VANNER Incorporated Owners Manual Table of Contents 1 Introduction.................................................................................................... 3 2 General Information ...................................................................................... 3 2.1 Introduction and Checkout ................................................................. 3 2.2 Specifications ..................................................................................... 4 2.3 Standard Features ...
VANNER Incorporated Owners Manual Introduction Thank you for purchasing the Vanner Max Battery Charger. We are confident that you will be satisfied with this charger's performance and its many features. With proper installation and care, you can look forward to years of service from this high performance product. This document will describe the operation, technical specifications, and installation procedures of this product.
VANNER Incorporated 1.2 Owners Manual Specifications Model Numbers SP00143, SP00180, SP00181 Input SP00155 SPC0184 SPC0182 SPC0187 15A at 120VAC ±10%, 60Hz ±10% Output 42A at 24VDC Nominal, 4AWG cables DC Current Draw with no AC voltage applied 30 milliamps “AC is connected” Output Signal, 4A max Bulk Voltage (Nominal) Ground (B-) +24VDC (B+) 28.6VDC Absorption Time Float Voltage (Nominal) Ambient Temperature 30 milliamps None Ground (B-) 29.8VDC 20 Minutes 26.6VDC 27.
VANNER Incorporated Owners Manual 2 Installation Instructions These symbols are used to note procedures that if not closely followed could lead to loss of life or damage to equipment or property due to electrocution. Electrocution hazard exists Fire hazard exists A potentially dangerous condition Explosive hazard exists Corrosive hazard exists Fault protection devices must be installed between the charger and the battery.
VANNER Incorporated Owners Manual 2.1 General Precautions Do not expose the charger to direct water spray or snow. To reduce the risk of a fire hazard, do not cover or obstruct the ventilation openings. Do not install the charger in a zero clearance compartment. This may result in overheating or diminished performance. To avoid the risk of fire, electrical shock, or injury to persons, do not use attachments not recommended or sold by the Vanner Inc.
VANNER Incorporated Owners Manual To reduce the risk of battery explosion, follow these instructions, the battery manufacturer instructions, and the instructions of the manufacturer of the equipment in which the battery is installed. Working near a lead-acid battery is dangerous. Batteries generate explosive gases during normal battery operation. 2.2 Battery Precautions 1. Always have someone within range of your voice to come to your aid when you work near a lead-acid battery. 2.
VANNER Incorporated 3.2 Owners Manual Charger Mounting • Install the MAX Charger in the horizontal upright position. The charger is furnished with mounting brackets which provide adequate clearance for under chassis airflow. The charger requires under chassis airflow for proper cooling. 3.3 Routing and Connecting Battery Charger Output Cables This Charger is designed for 24 VDC applications only. If connected to other than 24V system, damage will result.
VANNER Incorporated Owners Manual 4 Battery Charger Operation 4.1 Charger ON/OFF Control 1. There is no ON/OFF switch. Turn the charger ON by connecting the AC input line cord to a 15 Amp 120 Volt 60Hz power source. Turn the charger OFF by disconnecting AC power. 2. The charger will not accept AC power above 65Hz or voltage below approx 100 VAC. 4.2 Description of the Three Battery Charging Stages 1. Charging begins when the unit receives 120VAC shore power.
VANNER Incorporated Owners Manual 5 Operation LED Status Indicators for Models SP00143, SP00180, SP00181 and SPC0187 LED Charger Status Yellow solid The charger is ON and is in Bulk Stage or Absorption Stage. Green solid The charger is ON and is in Float Stage. Red solid The charger is OFF because internal temperature is too high. Shutdown may have been caused by high ambient temperature or by restricted cooling air flow.
VANNER Incorporated Owners Manual Notes: Max Battery Charger Page 11 Owner’s Manual
VANNER Incorporated Owners Manual Vanner Incorporated 4282 Reynolds Drive Hilliard, Ohio 43026 1-800-AC POWER (1-800-227-6937) Tel: 614-771-2718 Fax: 614-771-4904 www.vanner.com e-mail: pwrsales@vanner.