Operating instructions
21
Specifi cations
(Basic unit without extensions)
Main supply (L1, L2, L3)
Supply voltage 200 – 240 V ±10%
Supply voltage 380 – 480 V ±10%
Supply voltage 525 – 600 V ±10%
Supply voltage 525 – 690 V ±10%
Supply frequency 50/60 Hz
Displacement power factor
(cos ф) near unity
> 0.98
Switching on input supply
L1, L2, L3
1–2 times/min.
Harmonic disturbance Meets EN 61000-3-12
Output data (U, V, W)
Output voltage 0 – 100% of supply voltage
Output frequency 0–1000 Hz
Switching on output Unlimited
Ramp times 1 – 3600 sec.
Digital inputs
Programmable digital inputs 6*
Changeable to digital output 2 (terminal 27, 29)
Logic PNP or NPN
Voltage level 0 – 24 V DC
Maximum voltage on input 28 V DC
Input resistance, Ri Approx. 4 kΩ
Scan interval 5 ms
* 2 can be used as digital outputs
Analog inputs
Analogue inputs 2
Modes Voltage or current
Voltage level 0 to +10 V (scaleable)
Current level 0/4 to 20 mA (scaleable)
Accuracy of analog inputs Max. error: 0.5% of full scale
Pulse inputs
Programmable pulse inputs 2*
Voltage level 0 – 24 V DC (PNP positive logic)
Pulse input accuracy
(0.1 – 1 kHz)
Max. error: 0.1% of full scale
* Utilize some of the digital inputs
Digital outputs
Programmable
digital/pulse outputs
2
Voltage level at
digital/frequency output
0 – 24 V DC
Max. output current
(sink or source)
40 mA
Maximum output frequency
at frequency output
0 to 32 kHz
Accuracy on frequency
output
Max. error: 0.1% of full scale
Analog output
Programmable
analog outputs
1
Current range at
analogue output
0/4 – 20 mA
Max. load to common at
analogue output (clamp 30)
500 Ω
Accuracy on analog output Max. error: 1% of full scale
Control card
USB interface 1.1 (Full Speed)
USB plug Type “B”
RS485 interface Up to 115 kBaud
Max. load (10 V) 15 mA
Max. load (24 V) 200 mA
Relay output
Programmable relay outputs 2
Max. terminal load (AC)
on 1-3 (break), 1-2 (make),
4-6 (break) power card
240 V AC, 2 A
Max. terminal load (AC) on
4-5 (make) power card
400 V AC, 2 A
Min. terminal load on
1-3 (break), 1-2 (make),
4-6 (break), 4-5 (make)
power card
24 V DC 10 mA, 24 V AC 20 mA
Surroundings/external
Enclosure
IP: 00/20/21/54/5566
UL Type: Chassis/1/12/4x Outdoor
Vibration test 1.0 g (D, E & F-enclosures: 0.7 g)
Max. relative humidity
5% – 95% (IEC 721-3-3; Class 3K3
(non-condensing) during operation
Ambient temperature Max. 50° C wo. derating
Galvanic isolation of all I/O supplies according to PELV
Aggressive environment
Designed for coated/uncoated
3C3/3C2 (IEC 60721-3-3)
Fieldbus communication
Standard built-in:
FC Protocol
N2 Metasys
FLN Apogee
Modbus RTU
BACnet (embedded)
Optional:
LonWorks (MCA 108)
BACnet (MCA 109)
Profi bus (MCA 101)
DeviceNet (MCA 104)
Protection mode for longest possible up-time
– Electronic thermal motor protection against overload
– Temperature monitoring of the heatsink ensures that the frequency
converter trips if the temperature reaches 95° C ± 5° C.
– The frequency converter is protected against short-circuits on motor
terminals U, V, W.
– The frequency converter is protected against earth faults on motor
terminals U, V, W.
– Protection against mains phase loss
Global Marine