Operating instructions
Installation of options is a matter of plug-and-play
VLT® HVAC Drive A Options
VLT® LonWorks MCA 108
VLT® BACnet MCA 109
VLT® DeviceNet MCA 104
VLT® PROFIBUS DP V1 MCA 101
LonWorks is a fi eldbus system developed for building 
automation. It enables communication between 
individual units in the same system (peer-to-peer) and 
thus supports decentralising of control.
 ■ No need for big main station (master-follower)
 ■ Units receive signals directly 
 ■ Supports Echelon free-topology interface 
(fl exible cabling and installation)
The open communications protocol for worldwide 
building automation use. The BACnet protocol is an 
international protocol that effi ciently integrates all 
parts of building automation equipment from the 
actuator level to the building management system.
 ■ BACnet is the world standard for building 
 automation
 ■ International standard ISO 16484-5 
 ■  With no license fees, the protocol can be used in 
building automation systems of all sizes
 ■ This modern communications model off ers key 
 capabilities that let you eff ectively determine 
what information is needed and when
 ■ You will also benefi t from ODVA’s strong 
 conformance testing policies, which ensure that 
products are interoperable
 ■ PROFIBUS DP V1 gives you wide compatibility, a 
high level of availability, support for all major PLC 
vendors, and compatibility with future versions 
 ■ Fast, effi  cient communication, transparent installa-
tion, advanced diagnosis and parameterisation and 
auto- confi guration of process data via GSD-fi le
 ■ A-cyclic parameterisation using PROFIBUS DP V1, 
 PROFIdrive or Danfoss FC profi le state machines, 
 PROFIBUS DP V1, Master Class 1 and 2
 ■ Supports embedded I/Os and I/O options (easy 
implementation of de-central I/Os) 
 ■ Sensor signals can quickly be moved to another 
controller via bus cables
 ■ Certifi ed as compliant with LonMark ver. 3.4 
 specifi cations 
Ordering number 130B1106 uncoated – 130B1206 coated 
(Class 3C3/IEC 60721-3-3)
 ■  The BACnet option lets the drive communicate with 
building management systems running the BACnet 
protocol
 ■  Typical areas where BACnet is used include heating, 
 ventilation, cooling and climate equipment control
 ■  The BACnet protocol is easily integrated into exist-
ing control equipment networks
Ordering number 130B11446 uncoated – 130B1244 
coated (Class 3C3/IEC 60721-3-3)
Ordering number 130B1102 uncoated – 130B1202 coated 
(Class 3C3/IEC 60721-3-3)
Ordering number 130B1100 uncoated – 130B1200 coated 
(Class 3C3/IEC 60721-3-3)