Owners Manual
-40ºF to +125ºF (-40ºC to +52ºC)Temperature Range:
D913803, NOV-2014
Vanner, Inc.
GENERAL
SPECIFICATIONS
VSS-C80, VSS-C600, VSS-C80/600
Owners Manual
Vanner VSS Series Current Sensors are designed to operate in the most severe environments. The Current Sensor use
Industry Standard Deutsch connectors for ease of integration. The housing is constructed from high strength Glass Filled
Polycarbonate, for mounting using #10 or M5 hardware. The DC cable opening will accept up to 4/0 cable with a typical
4/0 lug attached. All desired loads to be monitored must be wired through the appropriate current sensor.
During installation the arrow must point;
Towards the battery if installed on the Positive cable
Away from the battery if installed on the Negative cable.
Supply Voltage:
Supply Current:
Load Resistance:
4.5 - 5.5 Vdc
25 mA
10kΩ
Output Voltage: .5 - 4.5 V
Weight: < 1.0 Lbs.
Required mating Deutsch connection as follows:
Housing: DT04-6P
Lock: W6P
Sealing Pin: 0413-217-1605
Terminal: 0460-202-16141 Solid or
1060-16-0122 Stamped,
16-18AWG
Sensitivity: @5V supply Voltage
VSS-C80
VSS-C600
VSS-V80/600
Sensitivity is dependant on the Supply Voltage
23.75 mV/A
3.17 mV/A
23.75,3.17 mV/A
Max Current:
VSS-C80
VSS-C600
VSS-V80/600
80 Amps
600 Amps
600 Amps
Deutsch Pinout:
1. Red +5V Input
2. Black Ground
3. Green Current Sense, 80A or 600A.
4. White Current Sense, 600A only, Dual
core only.
5. Orange Spare
6. Blue Spare
7.0" ±0.50"
Offset: 50% of the supply Voltage
INCORPORATED