Specifications
LA Series Linear Servo Amplifier Technical Reference Manual
12
7 LA-415 Jumper Settings
JP1 JP2
A B C D E F G H A B C D E F
JP3
Figure 2. Jumper Locations
JP1
Overcurrent Trip Level
Trip Current JP1-A JP1-B
2.0 Amps Open Open
3.0 Amps In Open
4.0 Amps Open In
5.0 Amps In In
Overcurrent Trip Time
Trip Time JP1-C JP1-D
1.25 Sec Open Open
2.5 Sec In Open
5 Sec Open In
10 Sec In In
Absolute Overcurrent Trip Level
Trip Current JP1-E JP1-F
12.0 Amps Open Open
15.0 Amps In Open
18.0 Amps Open In
20.0 Amps In In
JP1-G, Not Used. See Note
Motor Reverse Selection (Hall Mode)
Mode JP1-H
JP2
Sine/Hall Mode Selection*
Mode JP2-A
Sine Mode Open
Hall Mode In
*See Note 3
Input Filter Setting
Filter JP2-B JP2-C
500 Hz Open Open
800 Hz In Open
15 kHz Open In
32 kHz In In
Transconductance Ratio Setting
Ratio JP2-D JP2-E
0.8 Open Open
1.0 In Open
1.2 Open In
1.5 In In
Input DAC Selection
DAC Input JP2-F
Differential (Bipolar) Open
Single Ended (Unipolar) In
Normal Open
JP3
Reverse In
Current Loop Bandwidth Setting
Bandwidth JP3-A JP3-B
Contact Open Open
Factory In Open
For Open In
Settings In In
Note1: Jumper settings are only updated following a reset or POR of the drive.
Note2: If no jumpers are installed on JP1, JP2 and JP3, the parameters will be set via software.
Note 3: If using jumpers in Sine Mode with minimum settings (no jumpers), install a jumper on JP1-
G to force the drive to use the jumper settings. This prevents the drive from using software settings
as described in Note 2.
A B
See factory supplied configuration sheet
for “as delivered” amplifier values.