The 7 segment LED display on the front panel shows the status of the controller in real-time. The following
table lists the front panel LED display codes and their meaning. If multiple errors are present, the display
will cycle through all the error codes, displaying each for ½ second. Most errors can be reset by either
pressing the front panel pushbutton switch or cycling power to the unit, although some errors cannot be
fixed in the field. Please contact the factor for assistance with any errors that do not clear after a reset.
Ok, motor current enabled. This is the “normal” display when enabled
.
DSP Fault – Set when the internal DSP checksum fails following reset
NVM Fault – Set when NVM checksum fails following reset. Parameter
defaults are set.
Internal +5vdc – Set when the internal +5vdc supply is out of range
Autobalance Fault – Set when autobalance can’t balance amplifier outputs.
ABS Overcurrent – Set when instantaneous overcurrent condition is detected
SOA – Set when Safe Operating Area protection detects an over power
condition.
Internal +5 vdc Reference error – Set when internal +5 reference supply is out of range
Bus Over Voltage – Set when the internal motor bus voltage is greater than +/-75 vdc.
Ok, not enabled (Output is Clamped off). This is the normal display when not enabled.
Internal +2.5 vdc Reference error – Set when internal 2.5vdc supply is out of range.
Fatal Error – Set if the DSP encounters an unidentified problem.