Technical data
17.12.2004 Rev. 2.0
Adjustment instructions
14
The adjusting diameter shall be measured inside between the bowl arms:
Adjusting diameter:
• AR30 = 361,8mm
• AR40 = 391,3mm
• AR60 = 450,4mm
6.3.1 Adjustment of bowl centering
Loosen the counter nuts (1) and remove the cotterpins (2). Turn the bolts (3) until the bowl
is in the centre of the mixer. In order not to alter the fixing of the bowl, one of the bolts
must be turned out of the extension tube and the other into the extension tube. Use the flat
beater to check that the bowl is correctly centered and turn the planetary head with your
hand before the voltage is connected.
6.3.2 Adjustment of bowl height
The distance (X) is measured from the bottom side of the bayonet hole to the surface on
the bowl arms on which the bowl rests (fig.7a). The bowl arms must be lifted to normal
working position.
AR30 = 162mm
X: AR40 = 162mm
AR60 = 178mm
ILJD