Datasheet

Subject to change without notice
Variohm EuroSensor - Williams‘ Barn - Tiffield Road -Towcester - Northants -NN12 6HP - UK
sales@variohm.comwww.variohm.com+44 (0) 1327 351004
• Aluminium-AlloyIP65singlepointloadcell
• Colourlessanodized
• Suitableforpricingscales,
benchscales,etc.
• Maximumplatformsize:200x200mm
LoadCell-AL6BSeries
Outline dimensions in mm
Wiring
• Shielded, 4 conductor cable
• Cable diameter: Ø3mm
• Standard cable length: 0.40m
• Shield not connected to element
• Cable jacket in PVC
4-wire diagram
Input(+)
Output(-)
Input (-)
Output(+)
Red
White
Black
Green
Load Cell AL6B - 15/01
Capacity Accuracy Part-Number
0.3 kg L/H L6B-L/H-0.3kg-0.4B
0.6 kg L/H L6B-L/H-0.6kg-0.4B
1.0kg L/H L6B-L/H-1.0kg-0.4B
1.2 kg L/H L6B-L/H-1.2kg-0.4B
1.5 kg L/H L6B-L/H-1.5kg-0.4B
3.0 kg L/H L6B-L/H-3.0kg-0.4B
Specification
Accuracyclass
L H
Outputsensitivity(=FS)
mV/V 0.9 ± 0.1
Maximumcapacity(E
max
)
kg 0.3, 0.6, 1.0, 1.2, 1.5, 3
Linearity
%FS ≤± 0.015 ≤± 0.012
Hysteresis
FS ≤± 0.015 ≤± 0.012
Repeatability
%FS ≤± 0.015 ≤± 0.012
Temperatureeffectonminimumdeadloadoutput
%FS/10˚C ≤± 0.030 ≤± 0.020
Creeperror(2minutes)
%FS ≤± 0.010 ≤± 0.005
Eccentricloadingerror
% ≤± 0.0200
Minimumdeadload
OfEmax 0%
Safeoverload
OfEmax 120 %
Ultimateoverload
OfEmax 150 %
Zerobalance
ofFS < ± 2.0 %
Excitation,recommendedvoltage
V 5 ~ 12
Excitationmaximum
V 18
Inputresistance
Ω 406 ± 6
Outputresistance
Ω 350 ± 3
Insulationresistance
≥5000 ( at 50VDC )
Compensatedtemperature
°C -10…+40
Operatingtemperature
°C -20…+50
Storagetemperature
°C -30…+60
Elementmaterial
Aluminium
IngressProtection(acc.toEN60529)
IP65

Summary of content (1 pages)