Safety data sheet

MATERIAL DATA SAFETY SHEET
Section 1: PRODUCT AND COMPANY IDENTIFICATION
Johnson Controls Battery Group Inc. EMERGENCY PHONE: 24 hours – (800) 424-9300
(CHEMTREC)
Power Solutions INFORMATION PHONE: (800) 333-2222 ext. 3138
5757 Green Bay Avenue
Glendale, Wisconsin
PRODUCT NAME: Lead/acid Battery, Wet, filled with acid
MSDS NUMBER: L8 REVISON NUMBER: 2
DATE OF PREPARATION/REVISION: 07/20/2010
Section 2: COMPOSITION/INFORMATION INGREDIENTS
Material % by Wt. CAS Number Eight Hour Exposure Limits
OSHA
PEL
ACGIH
TLV
NIOSH
REL
Lead
34
7439-92-1
50 μg/m
3
150 μg/m
3
100 μg/m
3
Lead Oxide
31
1309-60-0
50 μg/m
3
150 μg/m
3
100 μg/m
3
Lead Sulfate (Anglesite)
<1
7446-14-2
50 μg/m
3
150 μg/m
3
100 μg/m
3
Battery Electrolyte
(Sulfuric Acid (35%)
34
7664-93-9
1mg/m
3
0.2 mg/m
3
(respirable thoracic
fraction)
1 mg/m
3
Section 3: HAZARDS IDENTIFICATION
NOTE: Under normal conditions of battery use, internal components will not present a health hazard.
The following information is provided for battery electrolyte (acid) and lead for exposure that may occur
during battery production or container breakage or under extreme heat conditions such as fire.
EMERGENCY OVERVIEW:
Acid filled battery. Contact with the electrolyte will cause burns to the eyes and skin. Contains lead. Absorption
of lead potentially may cause poisoning and reproductive effects.
ROUTES OF ENTRY:
EYE CONTACT: Contact with the battery electrolyte can cause severe irritation, burns, and cornea damage
upon contact.
SKIN CONTACT: Battery electrolyte (acid) can cause severe irritation, burns and ulceration.
SKIN ABSORPTION: Not a significant route of entry.
5

Summary of content (5 pages)