Technical data

OPEL MOVANO (X62)
105 – CAN BUS- INTERFACE MODULE, “KC6” OPTION
Note:
Subject to errors and technical amendments. The electronic version of the body guidelines is the decisive source of
up-to-date data on body guidelines (online body guidelines). Data status October 2012
Name of Field: ADAP Base 2
Description
Size
(bits)
MSB position State of input data Resulting output data bits
Flashing Indicators
(right/ left )
1
Byte no. 1 –
Bit no. 0
00 Flashing indicators
and hazard lights OFF
0
01 Flashing indicator ON
and hazard lights OFF
1
10 Flashing indicator ON
and hazard lights OFF
1
11 Hazard lights ON and
flashing indicator OFF
0
Hazard Light 1
Byte no. 2 –
Bit no. 7
00 Flashing indicators
and hazard lights OFF
0
01 Flashing indicator ON
and hazard lights OFF
0
10 Flashing indicator ON
and hazard lights OFF
0
11 Hazard lights ON and
flashing indicator OFF
1
****fixed to zero**** 7
Byte no. 1
Bit no. 6
LSB Octet Nº2 - Bit 0 **** fixed to zero ****
2) Binary outputs (for relay controls)
These 8 outputs comply with specification 36-00-100 UNI-B (45 mA, 10.5 at 16V)
CONFIGURATION OF OUTPUT DATA
Binary Output
Brake switch - engine control
Engine status
Clutch switch
Flashing indicators
Hazard lights
Ignition switch
Door switches
Doors locked
N.B.The max. current in unit output = 200mA
23