3-44 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Platinum VAX-C Series
3.6  Setup Screens - CTTB/CMMB Modulation
Figure 3-27 on left - CTTB Setup on right - CTTB Setup Screen 1
Table 3-22  Xmtr Home>Exciter Home>Setup>CTTB Modulator (screen 1)
Fields Explanation
Power-On Input The selected input, Primary (ASI 1) or Auxiliary (ASI 2), becomes the 
active input when the exciter is powered up.
Active Input The selected input, Primary (ASI 1) or Auxiliary (ASI 2), is the active 
input
Switching Mode Choices are Auto (automatic) or Manual switching of the ASI Transport 
stream. IF in the automatic mode and the current ASI stream has an issue 
or drops out, and the Auxiliary Input is set to Yes, the system will switch 
to the auxiliary ASI stream if it is available and good.
Network Operation: Choices are MFN (multiple frequency network) or SFN (single frequency 
network).
Consult the GB (National CTTB Standard of the People’s Republic of 
China) specification on proper modes of operation and make sure the 
transport stream input rate feeding the modulator is at or below the 
allowed rate for the mode desired. 
In MFN mode, the user can select the CTTB parameters that are allowed. 
Consult the GB spec on proper modes of operation and make sure the 
transport stream input rate you are feeding the modulator is at or below 
the allowed rate for the mode desired.
Auxiliary Input: Choices are No or Yes. If yes is selected the exciter can be made to switch 
to an auxiliary input if the active input faults or drops out.