User`s guide
7.1 INTRODUCTION
CHAPTER 7
CUSTOMER RUNNABLE DIAGNOSTICS
Customer runnable diagnostics or
CRD
is
a special control program to simplify the execution of micro-
and macrodiagnostics
in
the VAX-II diagnostic system
on
the
VAX-l1/730
system.
The
CRD
package operates
in
two modes: AUTO and MENU. In the AUTO mode, OFF-LINE bottom-
up testing
is
performed
on
the system without user intervention. In the
MENU
mode, the user
is
offered,
with menu prompts, the opportunity to further OFF-LINE test (beyond AUTO mode testing) any device,
including added options,
on
the system.
NOTE
Both
TU
58 tape drives, the removable media disk
drive, and the
console terminal are
used
for CRD, so
they must
be
functional.
For more information
on
customer runnable diagnostics, refer to the documentation entitled Customer
Runnable Diagnostics
User Guide.
7.2 CRD
MINIMUM
SYSTEM CONFIGURATION
The minimum
VAX-ll/730
system requirements
on
which CRD testing
is
performed must consist
of
the
following:
VAX-ll/730
Systems 1 and 2
•
VAX-l1/730
CPU
Cluster with
1M
bytes
of
Memory
• COMBO Board (DMF32)
• Dual TU58 Tape Drive
• Console Terminal
• IDC Board (RB730)
• RL02 Disk Drive
(DQAl)
• System Disk (either RL02 or R80) (DQAO)
• TU58
#34, VAX 11725/730 CONSOLE Tape Cartridge
• TU58 #36, VAX 11725/730 MICRODIAG Tape Cartridge
• RL02 #1, VAX 725/730 CMPLT DIAG Disk Cartridge
7-1