This command loads microdiagnostic section ENKBC from the microcassette.
INIT[IALIZE] - Initializes a WCS section. This command must be issued after a section
is
loaded by the
LD command before tests are executed.
It
is
automatically executed
in
a DI
SE
or DI command.
Example:
MIC>LD
EHKBC
MIC>IHIT
X/C
or
X/U
- Allows the remote diagnostic terminal to downline load a file into the console microproc-
essor memory (C for console memory) or WCS
RAM
(U for microcode). It
is
never executed from a
console terminal.
DI[AGNOSE] - The microdiagnostic unitspecified
is
loaded and run.
If
no unit
is
specified, then testing
starts at the first test and continues to the last test.
DI
[<keyword>]
Example:
MIC>DI
The following keywords may be used to modify the command.
BO[ARD]
CO[HTIHUE]
SE[CTIOHl
PA[SS]
TErST]
SH[ORTEH]
BOARD <type> - This keyword loads and executes all nonoptional sections that are associated with
either the WCS,
DAP, CPU, FPA,
MCT
or IDC board types.
NOTE
This command
is
incompatible with the SECTION
and TEST keywords.
Example:
MIC>DI
BO
DAP
Run those tests that exercise the DAP (M8394) board.
SECTION <section> - This keyword loads and executes the specified section from the microcassette.
Example:
MIC>DI
SE
EHKBC
Load and execute the tests that are included in section ENKBC.
TEST <number> - This keyword executes the specified test from the currently loaded section.
Example:
MIC>DI
TE
3
Run test number 3 of the section that
is
currently in
RAM
memory.
Example:
MIC>DI
TE
3 5
Run tests 3 through 5 of the section that
is
currently in
RAM
memory.
CONTINUE
- This keyword
is
used only after the
TEST
keyword.
It
executes the tests from the speci-
fied <number> to the end
of
the currently loaded section.
Example:
MIC>DI
TE
8
CO
B-2