User`s guide

PA[TT]*# - Read data from the IDC ECC pattern register.
Example:
MIC)EX
PA
- Examines the contents of the IDC Pattern Register (read only).
DB[UF]#
- Read/write data from/to the IDC's data buffer.
Examples:
MIC)EX
DB
- Examines the longword (four bytes) of the current data buffer (A or
B)
at
the
current data buffer address. The address
is
then incremented by four.
MIC)DE
DB
18FFCCA 1 - The value 18FFCCA 1
is
deposited
in
the current data buffer at the
current address. The address
is
then incremented by four.
UP[C] - Read/write
15
bits of data from/to the UPC register.
Examples:
MIC)EX
UP
- Examine the microprogram counter.
MIC)DE
UP
01F7C - Deposit the value 01F7C
in
the microprogram counter.
WC[S]
or
/C
- Read/write data from/to WCS (without parity calculation).
Examples:
MIC)EX
WC
OEOO
- Examine writable Control Store (WCS) or
EX/C
OEOO
through location
OEOO.
MIC)DE WC 0800 16574F - Deposit the value 16574F
in
WCS location 0800.
LS
- Read/write data from/to local store locations.
Examples:
MIC)EX
LS 200 - Examines the data
at
local store location 200.
MIC)DE LS 3100 3FF - Deposits the value 3FF
in
local store location 3100.
as - Read/write eight bits of data from/to the
CPU
as register.
Example:
MIC)EX
as - Examine the eight bits of data in the CPU as register.
UB[S]#
- Read/write data from/to the UNIBUS map portion of the translation buffer.
Examples:
MIC)EX
UB 200 - Read the location 200 from the UNIBUS translation buffer.
MIC)DE
UB 3FF IF900 - Writes data IF900 into location 3FF of the UNIBUS translation
buffer.
B-7